gefran EXP-MBTCP-ADV Manual
gefran EXP-MBTCP-ADV Manual

gefran EXP-MBTCP-ADV Manual

Modbus tcp/ip-rtu converter

Advertisement

Quick Links

Contents
1. Introduction ..........................................................................1
1.1. Applicability ....................................................................1
1.2. FW compatibility .............................................................1
1.3. Typical uses of the device ..............................................1
1.4. Specifications .................................................................2
1.5. Safety .............................................................................2
1.6. Montaggio ......................................................................2
1.7. Connectors ....................................................................2
1.8. LEDs and Switches ........................................................3
1.9. HW Reset .......................................................................3
1.10. Write protection ..............................................................3
1.11. MAC Address .................................................................3
2. Using the device ..................................................................4
2.1. Ethernet Communication ...............................................4
2.2. System requirements .....................................................4
2.3. Connection to the drive ..................................................4
3. Webapp GF_Bridge (Web Server).......................................5
3.1. Login and Access Levels Page ......................................5
3.2. Home page ....................................................................5
3.3. Parameters ....................................................................5
3.4. Transfer ..........................................................................6
3.5. Wizard ............................................................................6
3.6. Support ..........................................................................6
3.7. Info .................................................................................7
3.8. Settings ..........................................................................7
4. GF-eXpress Tool ..................................................................8
Manual download
Download the latest version of the manual from our website:
https://www.gefran.com/it/download/5802/attachment/en
https://www.gefran.com/it/download/5802/attachment/it
(EN)

1. Introduction

This manual describes the EXP-MBTCP-ADV optional board
(code S5L89), a serial/MODBUS TCP/IP interface converter.
The EXP-MBTCP-ADV board connects to the RS485 port of the
AD200 family of drives and has an RJ45 port for connection via
Modbus TCP/IP protocol - used for Drive-PC communication
(with GF_eXpress configuration software) - or via HTTPS pro-
tocol - for Drive-PC/network communication (with GF_Drivelabs
web application).
This manual is written for technicians and designers responsible
for the maintenance and initial start-up.

1.1. Applicability

The card is designed to be easily installed inside the ADV200
family of drives: ADV200, ADV200-WA, ADV200-LC, FFE200 and
AFE200.

1.2. FW compatibility

The EXP-MBTCP-ADV board can only be used with drives with a
firmware version:

1.3. Typical uses of the device

1.
2.
3.
4.
(IT)
Manuale scheda EXP-MBTCP-ADV - Pag. 1 / 8
EXP-MBTCP-ADV
Modbus TCP/IP-RTU Converter
Drive
ADV200
ADV200 WA
ADV200 LC
FFE200
AFE200
Device configuration with WEB-SERVER: via a WEB
page, the device enables configuration of the network and
MODBUS RTU communication;
Inverter data monitoring and configuration with GF-eXpress:
to read/write parameters and monitor FW and Application
parameters;
Communication with the drive makes the following possible:
debugging via Softscope,
creation of applications with MDPLC;
Multiple device accesses by several users:
the device with MODBUS TCP/IP can be used by several
users - up to a maximum of 5 simultaneous connections,
access to the WEB-SERVER configuration is permitted
for a single connection at a time. The user must log off to
enable a new connection.
Cod. 1S5L89 - 08/2022 - ENG
FW
4.X.0 or higher
2.X.0 or higher
7.X.17 or higher
1.X.0 or higher
7.1XX or higher

Advertisement

Table of Contents
loading

Summary of Contents for gefran EXP-MBTCP-ADV

  • Page 1: Table Of Contents

    2. Using the device ..............4 2.1. Ethernet Communication ..........4 1.2. FW compatibility 2.2. System requirements .............4 The EXP-MBTCP-ADV board can only be used with drives with a 2.3. Connection to the drive ..........4 firmware version: Drive 3. Webapp GF_Bridge (Web Server)........5 ADV200 4.X.0 or higher...
  • Page 2: Specifications

    RxB/TxB RS-485 IN-OUT Internal use 2) Position the EXP-MBTCP-ADV board (D) as shown in figure Internal use 2, inserting the board's RS-485 M connector (P2) all the way into the RS-485 F connector (XS), then fully tighten the two (J1) Ethernet RJ45 Connector screws on the connector (P2).
  • Page 3: Leds And Switches

    CONFIG menu), see chapter "3. Webapp GF_Bridge (Web Ser- S1-2 Reset to default configuration ver)" on page 5. ON = normal operation OFF = reset to default configuration Dip-switch position must only be changed with the device switched off Caution Manuale scheda EXP-MBTCP-ADV - Pag. 3 / 8...
  • Page 4: Using The Device

    The assigned DHCP can be obtained via the “ping” command issued from the “Command Prompt” by a PC running in the The drive can be connected to the EXP-MBTCP-ADV board via same subnet: a point-to-point connection with Static IP address (for direct PC/...
  • Page 5: Webapp Gf_Bridge (Web Server)

    The parameters in this menu display board information. Maximum response times on RTU network. 1000 Bridge status BRIDGE/INFO Display of a status WORD indicating device operation. The WORD is Parameter name Read composed as follows: Product S/N 41975605 Manuale scheda EXP-MBTCP-ADV - Pag. 5 / 8...
  • Page 6: Transfer

    Gefran website. Enters the network IP address. 9564 IP Netmask 255.255.0.0 Subnet IP address in use. 9566 IP Gateway 0.0.0.0 Gateway IP address in use. Manuale scheda EXP-MBTCP-ADV - Pag. 6 / 8...
  • Page 7: Info

    Info: displays the firmware version and EXP-MBTCP-ADV Card serial number. Clicking on Support calls up a list of all contacts for support, customer service and direct links to pages on the Gefran website. Account Settings: credentials management menu. Not available in Easy mode.
  • Page 8: Gf-Express Tool

    Select. GEFRAN DRIVES AND MOTION S.R.L. Via Carducci, 24 - 21040 Gerenzano [VA] ITALY Ph. +39 02 967601 - Fax +39 02 9682653 - info.motion@gefran.com - www.gefran.com Manuale scheda EXP-MBTCP-ADV - Pag. 8 / 8...

Table of Contents