Teka DH ISLA 120 Instruction Manual page 13

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
Accesories supplied
1
150/ 120 mm reduction.
4
Screws (M4 x 12).
4
Screws (M4 x 10).
6
Lock screws (Ø8 x 45).
8
Screws M4 x 16.
8
Ø6,4 x Ø12, washers.
Installation
Fig. 1 (Page 31)
On installing the kitchen hood make sure
that the Safety Instructions set out on page
10 are complied with.
To obtain optimum performance, the external
conduct must not be more than FOUR
METRES long, have no more than two 90°
angles and its diameter must be at least Ø120.
!
THE MOTOR POWER SUPPLY MUST BE
CONNECTED
BY
TECHNICAL SERVICE.
1) Using the support (O) trace and drill the where the
screw-fittings will sit onto the roof (S) (Ø8 x 45).
2) Screw the support (O) into the roof with the screw-
fittings (S) (Ø8 x 45).
3) Mount the upper chassis (A6) onto the support
(O) using the screws (Q) (M6 x 16).
4) Connect the upper part of the inner tube (not
supplied) to the exit.
5) Mount the upper cover (A8) and attach it to the
upper chassis (A6) with the screws (G) (M4 x 10).
6) Mount the lower chassis (A7) to the upper section,
attaching it to the roof using the screws (A10) (M4 x
12) at the required height.
7) Fit the part (B) if the inner tube (not supplied) is
Ø120.
8) Remove the metal filters. Loosen the screws
(without unscrewing them) of the EASYCLEAN
panels (A19), move the panels aside carefully and
take them off.
9) Mount teh body with the screws (A21) M4x16 )
with the washers (A22) (Ø6,4 x Ø12) throught the
inside of the kitcehn hood.
10) Attach the inner tube with a clamp (not supplied)
to (B) or on to the motor's air outlet vent as the case
may be.
11) Mount the lower part (A9a) of the cover to the
lower chassis (A7) with the screws (I) (M4 x 12).
12) Adjust the lower part (A9b) of the cover (A9a) as
shown in the diagrams.
13) Mount the EASYCLEAN panel again (A19). Fit
the metal filters.
AN
AUTHORIZED
Active charcoal filters (Optional)
When exterior gas extraction is not possible, then the
kitchen hood may be set to purify the air by recycling
it through active charcoal filters.
The active charcoal filters have an active life of
between three to six
individual conditions of use. These filters cannot be
washed nor regenerated. They must be replaced
once their useful life comes to an end.
Fig. 1 (Page 31)
1) Mount the diffuser support (A13) onto the
upper chassis (A6) with the screws (A4) (M4 x
12).
2) Adjust the diffuser (A5) over the support
(A13).
3) Connect the upper part of the inner tube (not
supplied) to the circular support exit (A13).
4) Using the support (O) trace and drill the
where the screw-fittings will sit onto the roof (S)
(Ø8 x 45).
5) Screw the support (O) into the roof with the
screw-fittings (S) (Ø8 x 45).
6) Mount the upper chassis
support (O) using the screws (Q) (M6 x 16).
7) Mount the upper cover (A8) and attach it to the
upper chassis (A6) with the screws (G) (M4 x 12).
8) Mount the lower chassis (A7) to the upper
section, attaching it to the roof using the
screws (A10) (M4 x 12) at the required height.
9) Fit the part (B) if the inner tube (not
supplied) is Ø120.
10) Remove the metal filters. Loosen the
screws (without unscrewing them) of the
EASYCLEAN panels (A19), move the panels
aside carefully and take them off.
11)
Mount teh body with the screws (A21) M4x16 )
with the washers (A22) (Ø6,4 x Ø12) throught the
inside of the kitcehn hood.
12) Attach the inner tube with a clamp (not
supplied) to (B) or on to the motor's air outlet
vent as the case may be.
13) Mount the lower part (A9a) of the cover to
the lower chassis (A7) with the screws (I) (M4
x 12).
14) Adjust the lower part (A9b) of the cover
(A9a) as shown in the diagrams.
15)
Put the filters into the lateral draught
section of the motor making the holes in the
filters match up (A11) with the pivots (A12) of
the motor carcass.
16) Mount the EASYCLEAN panel again (A19).
Fit the metal filters.
months, depending on the
(A6) onto the
13

Advertisement

Table of Contents
loading

Table of Contents