Maintenance - PRO STORMER BDP40020 Instruction Manual

Submersible water pump
Table of Contents

Advertisement

The device switches off after a brief runtime:
Check whether the water temperature is too high. The device might have overheated
due to a too high water temperature and the thermal protection circuit is activated.
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check whether the hoses are blocked and whether the water contains any suspended
matter with a particle size of more than 1/2 inch, which could clog up the device. The
device might have overheated due to the blockage and the thermal protection circuit is
activated.
Insufficient or decreasing conveying capacity:
Check whether the hoses are blocked and whether the water contains any suspended
matter with a particle size of more than 1/2 inch, which could clog up the device.
Check the hose diameter and the pump height. An excessive pump height paired with a
small hose diameter can cause a reduction of the conveying capacity.
Check whether the hose line is kinked or blocked. Remove kinks and / or blockages.
Notice
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device
back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to an authorized pecialist
electrical company for repair.

Maintenance

Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Notes on maintenance
Inside the device, there are no parts that need to be maintained or lubricated by the user.
Your submersible pump is more or less maintenance-free. The only tasks you must carry out
are as follow:
• Carry out a regular visual inspection. Make sure the pump is not damaged. Check the
electrical cable, the plug and the float switch for damage too. If you discover damage, you
must take the device to your supplier or an accredited professional. Never attempt to carry
out repairs yourself and never open the pump!
• Regularly check that the float switch is working effectively, particularly if you have set
the pump to work automatically(every 3 months). Regularly remove residues from the float
with clean water. Turn the pump upside­down, open the side-panel with a pin or similar and
18

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for PRO STORMER BDP40020

This manual is also suitable for:

Bdp75020

Table of Contents