1.
Hold onto the mains plug while pulling the power cable out of the mains socket.
2.
If necessary, pull the device out by means of the nylon cord.
3.
Clean the device according to the Maintenance chapter.
4.
Store the device according to the Storage chapter.

Errors and faults

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised
specialist companies.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
The device has been checked for proper functioning several times during production. If
malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check whether the float switch is located above the automatic switch-on position.
The device might have overheated and the thermal protection circuit is activated.
If so, wait for approx. 10 minutes before restarting the device. If the device is not
starting, have the electrics checked by a specialist company .
The water temperature is above 35 °C and the thermal protection circuit is activated.
Check whether there are any foreign objects in the air intake opening, the impeller, the
reducer (7) and / or the hose or pipe.
The device is running, but not pumping any water:
Check the inside of the device for any remaining air. To do so, lower the device into the
water at a slight angle and wait for the entire air to escape.
Check whether the minimum water level has been reached, see technical data. In order
to start pumping, the device requires a minimum water level.
Check whether the hoses are blocked and whether the water contains any suspended
matter with a particle size of more than 16 mm, which could clog up the device.
Check whether the used hose diameter is too small.
Check whether the hose line is kinked or blocked. Remove kinks and / or blockages.
Check reducer (7) for blockages.
The device is not switching off automatically:
The float switch is hindered from lowering. Check whether the float switch can move freely.
Remove any blockages or ensure sufficient freedom of movement for the float switch.