Manual On/Off: Press the FAN ON/OFF button once to manually turn fan on, and
again to turn fan off.
Countdown Timer: When the fan is turned on manually, the
countdown timer will run your fan for your selected period of
time, then turn your fan off.
Condensation Sensitivity: The minus sign is low condensation
(humidity) sensitivity and the plus sign is high sensitivity; the dial
can be set anywhere in between. In a very wet environment,
lower sensitivity may be needed to avoid excessive fan run-time.
In a very dry environment, higher sensitivity may be needed for
the sensor to detect condensation. When the CONDENSATION
SENSOR senses condensation, the BLUE LED LIGHT will pulse
slowly.
Setting Sensitivity: The dial is similar to a clock. The factory setting of the
condensation (humidity) sensitivity dial is set to the noon position. If you feel the
factory setting is too slow in turning on your fan, turn the dial to the right an hour at
a time. Or, if you feel the factory setting turns your fan on too quickly, turn the dial to
the left an hour at a time until the desired sensitivity level is reached.

Testing The Control

1.) After you have completely installed the CONTROL, you can turn on the breaker
to apply power.
WARNING: If the breaker trips or the fuse blows, Stop and call a qualified
licensed electrician to investigate the problem. Turn the breaker off until the
problem has been corrected.
2.) Press the FAN ON/OFF button to see the fan turn on, press the button again to
see the fan turn off.
3.) With the fan off, you can test the CONDENSATION SENSOR by blowing into
the sensor as if you were blowing on a mirror to steam it. Use three puffs of breath
and the fan will come on automatically. The BLUE LED LIGHT will pulse slowly; this
shows you the CONTROL is sensing condensation.
4.) Sensor Shut-Off: To turn off the sensor and make the control just a manually
activated adjustable timer, hold down the FAN ON/OFF button for 15 seconds. To
enable the sensor again, simply repeat the process.