REVENT RVH50 Installation Manual page 15

Table of Contents

Advertisement

WARNING: Disconnect the AC power before any work is done to any part of
the circuit ReVent is connected to. If you do not understand this warning,
seek the services of a qualified licensed electrician.
WARNING: Copper to copper only. Do not use aluminum wire.
WARNING: Follow all local electrical and safety codes, and NEC (National
Electrical Codes).
CAUTION: If your house wires do not match these colors, determine what
each house wire represents before connecting. You may need to consult a
qualified licensed electrician to determine this safely.
6.) Open the electrical enclosure inside the FAN and connect wiring using the
provided WIRE NUTS, matching wire colors as shown:
7.) When sheetrock is in place, p ress and bend the final securing tabs flat against
ceiling to lock the FAN in place.
final securing tabs
apply even
pressure to
each side of
securing tab
white / neutral
green /
green / ground
black / power
FAN
3 wires
14
QUICK CONNECT
OR WIRE NUT
Qty:3
120V Line AC
2 wires
2 wires
Close-Up
sheetrock
(ceiling)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rvh70Rvh80Rvh90Rvh110Rvh130Rvh150

Table of Contents