Nortek S4BE-018 Series Installation Instructions Manual

14 seer, single phase models
Hide thumbs Also See for S4BE-018 Series:

Advertisement

Quick Links

Split SyStem air conditioner
inStallation inStructionS
*S4Be / *Sa4Be - 018, 024, 030, 036, 042, 048, & 060 (1.5, 2, 2.5, 3, 3.5, 4, & 5 ton) SerieS
important
attention inStallerS:
it is your responsibility to know this product
better than your customer. this includes being
able to install the product according to strict
safety guidelines and instructing the customer
on how to operate and maintain the equipment
for the life of the product. Safety should
always be the deciding factor when installing
this product and using common sense plays
an important role as well. pay attention to
all safety warnings and any other special
notes highlighted in the manual. improper
installation of the furnace or failure to follow
safety warnings could result in serious injury,
death, or property damage.
these instructions are primarily intended to
assist qualified individuals experienced in the
proper installation of this appliance. Some
local codes require licensed installation/
service personnel for this type of equipment.
please read all instructions carefully before
starting the installation. return these
instructions to the customer's package for
future reference.
do not deStroy. pleaSe read careFully &
Keep in a SaFe place For Future reFerence.
14 Seer, Single phaSe modelS
air conditioner inStallation .................3
General Information ...........................................3
Before You Install this Unit .................................3
Locating the Air Conditioner ..............................3
Packaging Removal ...........................................3
Ground Level......................................................3
Roof Mount ........................................................3
Indoor & Outdoor Unit ........................................4
electrical Wiring ........................................4
Pre-Electrical Checklist ......................................4
Line Voltage .......................................................4
Grounding ..........................................................5
Diagnostics Module......................5
Compressor Protection ....................................5
Resetting Alert Codes ......................................5
Thermostat Connections ....................................6
Start up & adJuStmentS ...........................6
Pre-Start Check List ...........................................6
Start-Up Procedures ..........................................6
Air Circulation - Indoor Blower .........................6
System Cooling ................................................6
System Heating (optional) ................................6
air conditioner maintenance .................7
reFrigerant charging ..............................7
Charging the Unit in AC mode ...........................7
Figure 3. Charging Chart for 2 - 5 Ton Units ....8
electrical inFormation ............................9
Figure 4. Wiring Diagram for 1.5 - 4 Ton
Models (without CoreSense
Figure 5. Wiring Diagram for 1.5 - 4 Ton
Models (with CoreSense
Figure 6. Wiring Diagram for 5 Ton Models
(without CoreSense
Figure 7. Wiring Diagram for 5 Ton Models
(with CoreSense
Table 3. LED Diagnostics for CoreSense
Diagnostics Module ............................13
replacement partS .....................................16
TM
) .........9
TM
) ..............10
TM
) ......................11
TM
) ...........................12
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S4BE-018 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nortek S4BE-018 Series

  • Page 1: Table Of Contents

    Split SyStem air conditioner 14 Seer, Single phaSe modelS inStallation inStructionS *S4Be / *Sa4Be - 018, 024, 030, 036, 042, 048, & 060 (1.5, 2, 2.5, 3, 3.5, 4, & 5 ton) SerieS important important SaFety inFormation ....2 air conditioner inStallation ....3 General Information ...........3 attention inStallerS: Before You Install this Unit .........3...
  • Page 2: Important Safety Information

    important SaFety inFormation INSTALLER: Please read all instructions before servicing Warning: this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Safety the information listed below must be followed markings are used frequently throughout this manual to designate a degree or level of seriousness and should during the installation, service, and operation not be ignored.
  • Page 3: Air Conditioner Installation

    air conditioner inStallation packaging removal note: To prevent damage to the tubing connections, general information carefully remove the carton and user’s manual from the The S4BE series air conditioner is designed only for equipment. Discard the shipping carton. outdoor rooftop or ground level installations. This unit has been tested for capacity and efficiency in accordance ground level with AHRI Standards and will provide many years of safe...
  • Page 4: Connecting Refrigerant Tubing Between The Indoor & Outdoor Unit

    connecting refrigerant tubing Between electrical Wiring the indoor & outdoor unit Warning: caution: electrical ShocK or Fire haZard When servicing, cover or seal openings to to avoid risk of electrical shock, personal injury, minimize the exposure of the refrigerant system or death, disconnect all electrical power to the unit to air to prevent accumulation of moisture and before performing any maintenance or service.
  • Page 5: Grounding

    • Provide power supply for the unit in accordance with the Table 1 copper Wire SiZe — aWg unit wiring diagram, and the unit rating plate. Connect (1% Voltage drop) the line-voltage leads to the terminals on the contactor inside the control compartment. Supply Wire length-Feet Supply circuit •...
  • Page 6: Thermostat Connections

    thermostat connections Start up & adJuStmentS • Thermostat connections should be made in accordance pre-Start check list with the instructions supplied with the thermostat and √ Verify the indoor unit is level and allows proper the indoor equipment. condensate drainage. •...
  • Page 7: Air Conditioner Maintenance

    air conditioner maintenance • Refrigerant charging charts are applicable only to matched equipment and listed airflows for the indoor Warning: coil. Refer to Figure 3, (page 8) for correct system charging. • S4BE outdoor units with non-AHRI listed indoor coils to prevent electrical shock, personal injury, or are not recommended.
  • Page 8: Application Notes For Using The Charging Chart

    application notes for using the charging chart • This equipment’s cooling system contains Before using this chart, make sure the unit is in a stable refrigerant under high pressure. always use safe operating mode. As shown in Figure 3, (page 8), the and environmentally sound methods when handling ideal system sub-cooling can vary over the range of...
  • Page 9: Electrical Information

    electrical inFormation Figure 4 WIRING DIAGRAM Split System Air Conditioner (Outdoor Section) Single Phase NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3.
  • Page 10 Figure 5 Figure 5. Wiring diagram for 1.5 - 4 ton models (with coreSense...
  • Page 11 Figure 6 Figure 6. Wiring diagram for 5 ton models (without coreSense...
  • Page 12 Figure 7 Figure 7. Wiring diagram for 5 ton models (with coreSense...
  • Page 13: Diagnostics Module

    Table 3 alert code alert condition locK leVel locK indication normal run Normal operation, no trip Solid Yellow code1 Long run time. Compressor is on running for more than 18 hours. Yellow Flash 1 (Code1 is disabled in Heat Pump Mode) code2 Compressor (pressure) trip.
  • Page 16: Installation / Performance Checklist

    • Blower Assembly • Fan Grille • Cabinet Panels • Filter/Driers • Expansion Valves Specifications & illustrations subject to change without notice or incurring obligations (05/15). O’Fallon, MO, © Nortek Global HVAC LLC 2015. All Rights Reserved. 709606a (Replaces 7096060)

Table of Contents