Page 2
ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). ORing will repair or replace products found by ORing to be defective within this warranty period, with shipment expenses apportioned by ORing and the distributor.
Tables of Content Getting to Know your Wireless Media Gateway ......... 1 Overview ..........................1 Software Features ......................1 Hardware Features ......................2 Hardware Installation..................3 Installation Media Gateway on DIN-Rail ................3 Wall Mounting Installation ....................4 Hardware Overview..................6 Front Panel ..........................6 Front Panel LEDs .......................7 Bottom Panel ........................8...
Page 4
Date & Time..........................47 Login Setting..........................48 Media Gateway Restart ......................50 Firmware Upgrade ........................50 Save/Restore Configurations....................51 Miscellaneous (Ping)........................51 5.3.4 System Status ........................52 System Info ..........................52 System Log ..........................52 Traffic Statistics........................53 Wired/Wireless Clients................錯誤! 尚未定義書籤。 Technical Specifications ................54 ORing Industrial Networking Corp.
54Mbps. It is easy for you to extend the reach and number of computers connected to your wireless network. With build-in HSUPA WAN connection, the ORing IMG-1321-D wireless Media Gateway can be mounted in harsh environment easily to provide internet access anytime and anywhere.
4 digital inputs/outputs on terminal block Casing: IP-40 Dimensions(W x D x H) : 72(W)x29.4(D)x123.4(H) mm Operating Temperature: -10 to 60 Storage Temperature: -40 to 85 Operating Humidity: 5% to 95%, non-condensing ORing Industrial Networking Corp.
Media Gateway to fix on the DIN-Rail. Step 1: Slant the Media Gateway and mount the metal spring to DIN-Rail. Metal Spring Step 2: Push the Media Gateway toward the DIN-Rail until you heard a “click” sound. ORing Industrial Networking Corp……………………………………………………………….…3...
The following steps show how to mount the Media Gateway on the wall: Step 1: Remove DIN-Rail kit. Step 2: Use 6 screws that can be found in the package to combine the wall mount panel. Just like the picture shows below: ORing Industrial Networking Corp.
Page 10
IMG-1312-D User’s Manual The screws specification shows in the following two pictures. In order to prevent the Media Gateways from any damage, the screws should not larger than the size that used in IMG-1312-D. Pozidrive ORing Industrial Networking Corp……………………………………………………………….…5...
6. WLAN LED indicator, light up after the wireless is enable. 7. LED for PWR1 and system status. When the PWR1 links, the green LED will be light on. 8. LED for PWR2 and system status. When the PWR2 links, the green LED will be ORing Industrial Networking Corp.
WLAN signal strength. WLAN Green 1<25%, 2<50%, 3<75%, Strength 4<100% Green Modem Ready Green Blinking Serial port is transmitting data Serial Blinking Serial port is receiving data Green On/Blinking 100Mbps LNK/ACT ETH 1/2 Green/Amber Amber On/Blinking 10Mbps LNK/ACT ORing Industrial Networking Corp……………………………………………………………….…7...
IMG-1312-D User’s Manual Bottom Panel The bottom panel components of IMG-1312-D are shown as below: Rear Panel The rear panel components of IMG-1312-D are shown as below: 1. Screw holes for wall mount kit. 2. DIN-Rail kit ORing Industrial Networking Corp.
Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45 100BASE-TX/10BASE-T Pin Assignments With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6 are used for receiving data. RJ-45 Pin Assignments ORing Industrial Networking Corp……………………………………………………………….…9...
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair. Wireless Antenna A 2.4GHz antenna is used for IMG-1312-D and connected with a reversed SMA connector. External antenna also can be applied with this connector. ORing Industrial Networking Corp.
The default gateway IP of IMG-1312-D Media Gateway is 192.168.10.1. Start the web browser of your computer and type http://192.168.10.1 in the address box to access the webpage. A login window will popup, and then enter the default login name admin and password admin. Login ORing Industrial Networking Corp……………………………………………………………….…11...
Description Firmware Show the current firmware version. Uptime Show the elapsed time since the Media Gateway is started. Wan IP Show the WAN IP address. 5.3.1 Basic Setting The IMG-1312-D Media Gateway provide 3G WAN connection. ORing Industrial Networking Corp.
Click “Connect” to call up the Modem/3G. Click "Disconnect" to Operations shut down the connection. Link Status Show the status of connection, up, down or connecting. These are the IP settings of the LAN interface for the IMG-1312-D WLAN ORing Industrial Networking Corp……………………………………………………………….…13...
Set your computers to be DHCP clients by setting their TCP/IP settings to Obtain an IP Address Automatically. The DHCP server will allocate an unused IP address from the IP address pool to the requesting computer automatically. 1. DHCP Sever ORing Industrial Networking Corp.
Page 20
When a computer with the MAC address requesting an IP from the IMG-1312-D Media Gateway, it will be assigned with the IP address according to the mapping. You can choose one from the client lists and add it to the mapping relationship. ORing Industrial Networking Corp……………………………………………………………….…15...
Label Description Service Set Identifier (SSID) is a unique name that identifies a SSID network. All devices on the network must set the same SSID name in order to communicate on the network. If you change ORing Industrial Networking Corp.
Page 22
WPA/WPA2: Wi-Fi Protected Access (WPA) authentication in conjunction with a RADIUS server. Security Type – None No security protection for WLAN. Security Type – WEP Wireless Security Type-WEP ORing Industrial Networking Corp……………………………………………………………….…17...
Page 23
Choose one of three Auth Modes: WPAPSK, WPA2PSK, WPAPSK/WPA2PSK Encryption Type: Select TKIP or AES or TKIP/AES mix. Share Key: Enter your pass phase. The pass phase should be between 8 and 64 characters. Security Type – WPA /WPA2 ORing Industrial Networking Corp.
Page 24
Encryption Type: Choose one of three Encryption Types: TKIP, AES, TKIP/AES mix. Radius Server IP: Enter the IP address of the RADIUS Server. Port: Enter the RADIUS port (1812 is default). Shared Secret: Enter the RADIUS password or key. Security Type – 802.1X ORing Industrial Networking Corp……………………………………………………………….…19...
Page 25
ISA server may also refuse you to carry a claim according to the authorization strategy of the Radius server. The principle of the Radius server is shown in the following pictures: ORing Industrial Networking Corp.
Serial Setting Wireless 1. Remote Management Label Description Enable to allow DS-tool to access M2M through WAN Remote Management Enable to allow the serial port to be access through WAN Port External Access 2. Serial Configuration ORing Industrial Networking Corp……………………………………………………………….…21...
Page 27
0 means disable. Factory default value is 0. Throughput: This mode optimized for highest transmission speed. Performance Latency: This mode optimized for shortest response time. Apply Activate settings on this page. ORing Industrial Networking Corp.
Page 28
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be hold until the delimiters are received or the option “Flush Ethernet to Serial data buffer” times out. 0 means disable. Factory default is 0 4. Service Mode - – Virtual COM Mode ORing Industrial Networking Corp……………………………………………………………….…23...
Page 29
0 indicate disable this function. Factory default is 0. The number of Max connection can support simultaneous connections are 5, Max Connection default values is 1. *Not allowed to mapping Virtual COM from web 5. Service Mode – TCP Server mode ORing Industrial Networking Corp.
Page 30
0 indicate disable this function. Factory default is 0. The number of Max connection can support simultaneous connections are 5, Max Connection default values is 1. 6. Service Mode – TCP Client Mode In TCP Client Mode, device can establish a TCP connection with ORing Industrial Networking Corp……………………………………………………………….…25...
Page 31
Connect on Any The TCP Client will build TCP connection once the connected serial device Character starts to send data. 7. Service Mode – UDP Mode Compared to TCP communication, UDP is faster and more efficient. ORing Industrial Networking Corp.
5.3.3 Advanced Setting Wireless 1. Parameters Parameters The following table describes the labels in this . Label Description Beacon Interval The default value is 100. The Beacon Interval value indicates ORing Industrial Networking Corp……………………………………………………………….…27...
Page 33
BG Mixed mode. If you Wireless Network have only IEEE802.11g devices, select G Mode. If you would Mode like to limit your network to only IEEE802.11b devices, then select B Mode. ORing Industrial Networking Corp.
Page 34
Use MAC Filter to allow or deny wireless clients to associate with IMG-1312-D Media Gateway. You can manually add a MAC address or select the MAC address from Associated Clients that are currently associated with IMG-1312-D. ORing Industrial Networking Corp……………………………………………………………….…29...
Internet to this Local port will be redirected to the computer specified by the Local IP. Any PC that was used for a virtual server must have static or reserved IP Address because its IP address may change when requesting IP by DHCP. ORing Industrial Networking Corp.
Page 36
Some applications require multiple connections, like Internet games, video conferencing, Internet calling and so on. These applications cannot work with a pure NAT Media Gateway. Port Trigger is used for some of the applications that can work with an NAT Media Gateway. ORing Industrial Networking Corp……………………………………………………………….…31...
Page 37
Enter the IP address of the internal computer that will be the DMZ host. Adding a client to the DMZ may expose your local network with variety of security risks, so only use this option carefully. ORing Industrial Networking Corp.
Page 38
UPnP devices can be automatically discovered by the UPnP service application on the LAN. UPnP The following table describes the labels in this . Label Description Enable or disable UPnP. UPnP ORing Industrial Networking Corp……………………………………………………………….…33...
Filters are used to deny or allow LAN computers from accessing the internet. It also allow or deny WAN hosts to access LAN computers. IP Filter The following table describes the labels in this . Label Description ORing Industrial Networking Corp.
VPN Setting VPN Setting is settings that are used to create virtual private tunnels to remote VPN gateways. The tunnel technology supports data confidentiality, data origin, authentication and data integrity of network information by utilizing encapsulation ORing Industrial Networking Corp……………………………………………………………….…35...
Page 41
VPNs, WiFi security, and enterprise-scale remote access solutions with load balancing, failover, and fine-grained access-controls. Open VPN The following topology shows the common use of VPN connection from WAN side. 1: Open VPN Server ORing Industrial Networking Corp.
Page 42
The following table describes the labels in this . Description Label Enable or disable the function of Open VPN Client. You can Open VPN Client allow or deny the Open VPN Client with this option. ORing Industrial Networking Corp……………………………………………………………….…37...
Page 43
Keys Setting Select Auto to use the preset certificates, select Manual to paste your certificates. Please install software for openvpn client to generate your certificates and paste them here. For more information, please visit openvpn website. ORing Industrial Networking Corp.
Page 44
PC. The steps are: Right click Network > property > create a new connection > connect to my work space (VPN) > use VPN to internet > enter the user name and password which are set in the page. ORing Industrial Networking Corp……………………………………………………………….…39...
Page 45
IMG-1312-D User’s Manual PPTP VPN The following topology shows the common use of PPTP connection from the internet. Connection to PPTP VPN Server The following table describes the labels in this . ORing Industrial Networking Corp.
Page 46
3. PPTP Client If the Media Gateway A want to link with the others which is not in the same network with the Media Gateway A, the function of PPTP client should support in the Media Gateway page. ORing Industrial Networking Corp……………………………………………………………….…41...
Page 47
Point-to-Point Encryption) to encrypt data across Point-to-Point Protocol (PPP) and Virtual Private Network links. Operations Click “Connect” to link the server, if or not, you can click “”Disconnect” to break off from the server. Link Status Show the status about the link. ORing Industrial Networking Corp.
RIPv1 &v2 Choose “Disable” in the Static routing. Telnet Setting Only use in the Dynamic routing. Simultaneously, only use the Telnet function in the dynamic routing. You can telnet the LAN IP and there are many orders. ORing Industrial Networking Corp……………………………………………………………….…43...
Specify the port where MTA can be contacted via SMTP server. Server Port Username Username to login the E-mail address Password Password to login the E-mail address Sender address Sender E-mail address E-mail Address 1-4 Enter the mail addresses. ORing Industrial Networking Corp.
Page 50
Community is essentially password to establish trust between Community managers and agents. Normally "public" is used for read-write community. Specify sysLocation string. SysLocation Specify sysContact string. SysContact Syslog Server Settings Syslog Server The following table describes the labels in this . Label Description ORing Industrial Networking Corp……………………………………………………………….…45...
Page 51
Advanced Setting > Notification > System Event page. System Event System events record the activities of the Wireless Media Gateway system. When the setting changes or action performs, the event will be sent to administrator by email. ORing Industrial Networking Corp.
In this page, you can set the date & time of the device. The correct date & time will be helpful for logging of system events. A NTP (Network Time Protocol) client can be used to synchronize date & time with NTP server through internet. ORing Industrial Networking Corp……………………………………………………………….…47...
The secondary NTP Server. Synchronize This is the scheduled time when the NTP synchronization performed. Login Setting At this page, the administrator can change the login name and password. The default name and password is admin and admin. ORing Industrial Networking Corp.
Page 54
HTTPS are both supported. Port Choose the web management page port number. For HTTP, default port is 80; For HTTPS, default port is 443. HTTPS (HTTP over SSL) is a Web protocol which encrypts and decrypts user page ORing Industrial Networking Corp……………………………………………………………….…49...
Media Gateway. It will take several minutes to upload and update the firmware. After the upgrade is done successfully, reboot the Media Gateway to utilized new firmware. Important Notice: DO NOT POWER OFF THE MEDIA GATEWAY OR PRESS THE RESET BUTTON WHILE THE FIRMWARE IS BEING UPGRADED. ORing Industrial Networking Corp.
Restore Default Settings. The Media Gateway will reboot to validate the default settings. Miscellaneous (Ping) Miscellaneous The Ping Test is used to send Ping packets to test if a computer whether it is on the ORing Industrial Networking Corp……………………………………………………………….…51...
WAN, LAN and wireless settings. System Log System Log The Media Gateway keeps a running log of events and activities occurring on the Media Gateway, several filters are provided for displaying related log entries. ORing Industrial Networking Corp.
Click the button 'Refresh' to refresh the page. Click the button 'Clear Logs' to clear the log entries. Traffic Statistics Traffic Statistics This page displays the network traffic statistics for both received and transmitted packets through the Ethernet port and wireless connections. ORing Industrial Networking Corp……………………………………………………………….…53...
Need help?
Do you have a question about the IDS-1112 and is the answer not in the manual?
Questions and answers