Table of Content ....................1 ETTING TO EVICE ERVER About the IDS-5011F Serial Device Server..................1 Software Features ..........................1 Hardware Features ...........................2 ........................3 ARDWARE NSTALLATION Install IDS-5011F on DIN-Rail......................3 2.1.1 Mount IDS-5011F on DIN-Rail .....................3 Wall Mounting Installation .........................4 2.2.1 Mount IDS-5011F on wall......................5 ..........................8 ARDWARE VERVIEW...
Page 3
IDS-5011F Series User’s Manual 5.2.1.4 Save/Reboot........................51 Configuration by SSH Console .......................52 5.3.1 Connect to DS..........................52 ........................53 ECHNICAL PECIFICATIONS...
IDS-5011F Series User’s Manual etting to Know Your Device Server About the IDS-5011F Serial Device Server IDS-5011F is an innovative 1 port RS232/422/485 to 1 port fiber optical device server. The option of the fiber port can be multi-mode (IDS-5011F-MM)
IDS-5011F Series User’s Manual Various Windows O.S. supported: Windows NT(5.0)/2000/XP/2003/VISTA Hardware Features Redundant Power Inputs: 12~48 VDC on terminal block and power jack Operating Temperature: -10 to 60 Storage Temperature: -20 to 85 Operating Humidity: 5% to 95%, non-condensing Casing: IP-30...
IDS-5011F Series User’s Manual ardware Installation Install IDS-5011F on DIN-Rail Each IDS-5011F has a Din-Rail kit on rear panel. The Din-Rail kit helps IDS-5011F to fix on the Din-Rail. It is easy to install the IDS-5011F on the Din-Rail: 2.1.1 Mount IDS-5011F on DIN-Rail Step 1: Slant the IDS-5011F and mount the metal spring to Din-Rail.
IDS-5011F Series User’s Manual Step 2: Push the IDS-5011F toward the Din-Rail until you heard a “click” sound. Figure 2-2 Wall Mounting Installation Each IDS-5011F has another installation method for you. A wall mount panel can be found in the package. The following steps show how to mount the IDS-5011F on the wall:...
IDS-5011F Series User’s Manual 2.2.1 Mount IDS-5011F on wall Step 1: Remove Din-Rail kit. Figure 2-3 ORing Industrial Networking Corp.
Page 10
IDS-5011F Series User’s Manual Step 2: Use 6 screws that can be found in the package to combine the wall mount panel. Just like the picture shows below: Figure 2-4 The screws specification shows in the following two pictures. In order to prevent IDS-5011F from any damage, the size of screws should not be larger than the size that used in IDS-5011F.
Page 11
IDS-5011F Series User’s Manual Step 3: Mount the combined IDS-5011F on the wall. . Figure 2-6 ORing Industrial Networking Corp.
IDS-5011F Series User’s Manual ardware Overview Front Panel Figure 3-1 1. Product description of IDS-5011F. 2. LED for PWR1 and system status. When the PWR1 links, the green led will be light on. 3. LED for PWR2 and system status. When the PWR2 links, the green led will be light on.
IDS-5011F Series User’s Manual Front Panel LEDS The following table describes the labels that stick on the IDS-5011F. Color Status Description DC power 1 activated. PWR1 Green/Red Indicates an IP conflict, or DHCP or BOOTP Red blinking server did not respond properly DC power 2 activated.
IDS-5011F Series User’s Manual Top Panel The Top panel components of IDS-5011F are showed as below: 1. Terminal block include: PWR1 (12 ~ 48V DC) 2. Power Jack include: PWR2 (12 ~ 48V DC) 3. 100Base-FX Ethernet interface. Figure 3-2...
Page 15
IDS-5011F Series User’s Manual 1. Reset bottom. 5 seconds for factory default. 2. Male DB9 connector: Serial interface of RS-232/422/485 (2 wire)(4 wire). DB9 connector RS 485 RS 485 Pin # RS 232 RS 422 ( 4 wire ) ( 2 wire )
IDS-5011F Series User’s Manual Rear Panel The rear panel components of IDS-5011F are showed as below: 1. Screw holes for wall mount kit and DIN-Rail kit. 2. Din-Rail kit 3. Wall Mount kit. Figure 3-4 Rear Panel ORing Industrial Networking Corp...
IDS-5011F Series User’s Manual ables Fibers IDS-5011F has one fiber optical ports. The fiber optical port is multi-mode (0 to 2 km, 1310 nm, 50/125 µm to 62.5/125 µm) or single-mode (0 to 30 km, 1310 nm, 9/125 µm) with SC connector.
IDS-5011F Series User’s Manual anagement Interface DS-Tool DS-Tool is a powerful Windows utility for DS series. It supports device discovery, device configuration, group setup, group firmware update, monitoring functions...etc. It is easy for you to install and configure devices over the network.
Page 19
IDS-5011F Series User’s Manual Step 2: When installation complete successfully, then click “OK”. Figure 5-2 Step 3: Check for your selection. Figure 5-3 ORing Industrial Networking Corp.
IDS-5011F Series User’s Manual 5.1.2 Using DS-Tool 5.1.2.1 Explore device servers DS-Tool will broadcast to the network and search all available DS devices in the network. The default IP address of device is “192.168.10.2”, and selects the searching device you wish to use and press “Add” button.
IDS-5011F Series User’s Manual 5.1.2.2 Configure device servers General settings This page includes the setting of device name, SNTP server and Auto IP Report. Figure 5-5 General settings The following table describes the labels in this screen. Label Description You can set the device name or related information. By clicking “Locate On” button you Device Name/location can locate the serial server’s position.
Page 22
IDS-5011F Series User’s Manual By Clicking the “Get current Host” button you will get your local IP, and then set the Set Auto IP Report Report interval time. The device server will report its status periodically. Table 5-1 General settings At IP collection option show the device server status.
Page 23
IDS-5011F Series User’s Manual Network Setting Device DS can connect the Network by wire . You must assign a valid IP address for DS before attached in your network environment. Your network administrator should provide you the IP address and related settings. The IP address must be unique within the network (otherwise, DS will not have a valid connection to the network).
Page 24
IDS-5011F Series User’s Manual The following table describes the labels in this screen. Label Description Using DHCP/BOOTP IP Address automatically assigned by a DHCP server in your network. Static IP Address Manually assigning an IP address. All devices on the network must have the same subnet mask to communicate on the Subnet Mask network.
Page 25
IDS-5011F Series User’s Manual Notification Specify the events that should be notified to the administrator. The events can be alarmed by E-mail, SNMP trap, or system log. Figure 5-8 Notification The following table describes the labels in this screen. Label...
Page 26
IDS-5011F Series User’s Manual Management Figure 5-9 Management The following table describes the labels in this screen. Label Description To enable management from Web. Click “Goto Web Management” button to Web Management Enable access web. To enable management by Telnet. Click “Goto Telnet Management” button to Telnet Management Enable execute Telnet command.
Page 27
IDS-5011F Series User’s Manual Upgrade Firmware Figure 5-10 Upgrade Firmware The following table describes the labels in this screen. Label Description Browsing Browse the file and upgrade Upgrade Enable the firmware upgrade. Table 5-5 Upgrade Firmware Save/Load Figure 5-11 Save / Load The following table describes the labels in this screen.
IDS-5011F Series User’s Manual Load default configuration except the network settings. If you want to load all factory Load Default default, you need to press “Reset” button on the device (Hardware restore). Reboot Device Reboot the device server (warm start).
Page 29
IDS-5011F Series User’s Manual The following table describes the labels in this screen. Label Description Port Alias Remark the port to hint the connected device. Interface RS232 / RS422 / RS485(2-wires) / RS485(4-wires) 110bps/300bps/1200bps/2400bps/4800bps/9600bps/19200bps/ Baud rate 38400bps/57600bps/115200bps/230400bps/460800bps Data Bits 5, 6, 7, 8 Stop Bits 1, 2 (1.5)
Page 30
IDS-5011F Series User’s Manual Force TX interval time is to specify the timeout when no data has been transmitted. Force TX Interval Time When the timeout is reached or TX buffer is full (4K Bytes), the queued data will be sent.
Page 31
IDS-5011F Series User’s Manual The following table describes the labels in this screen. Label Description Map Virtual COM Select a Virtual COM Name to map on. The number of Max connection can support simultaneous connections are 5, default Max Connection values is 1.
Page 32
IDS-5011F Series User’s Manual Figure 5-13 TCP Server mode The following table describes the labels in this screen. Label Description Data Port Set the port number for data transmission. Auto Scan Scan the data port automatically. When serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts.
Page 33
IDS-5011F Series User’s Manual Service Mode – TCP Client Mode In TCP Client Mode, device can establish a TCP connection with server by the method you have settled (Startup or any character). After the data has been transferred, device can disconnect automatically from the server by using the TCP alive check time or Idle time settings.
Page 34
IDS-5011F Series User’s Manual When serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to Idle Timeout connect with other hosts. 0 indicate disable this function. Factory default value is 0.
Page 35
IDS-5011F Series User’s Manual Figure 5-15 UDP mode Notification Specify the events that should be noticed. The events can be noticed by E-mail, SNMP trap or system log. ORing Industrial Networking Corp.
Page 36
IDS-5011F Series User’s Manual Figure 5-16 Notification The following table describes the labels in this screen. Label Description When DCD (Data Carrier Detect) signal changes, it indicates that the modem DCD changed connection status has changed. Notification will be sent.
IDS-5011F Series User’s Manual In TCP Server/Client Mode, when the device lost the TCP link, this event will be trigger. Port disconnected In Virtual COM Mode, When Virtual COM is not available, this event will be trigger. A notification will be sent.
Page 38
IDS-5011F Series User’s Manual Step 3: Input the name and password, then click “OK”. Figure 5-17 Certificate *Only if password is set. Step 4: The system information will be shown as below. Figure 5-18 System information ORing Industrial Networking Corp...
IDS-5011F Series User’s Manual 5.2.1.1 System Time (SNTP) Figure 5-19 Time (SNTP) The following table describes the labels in this screen. Label Description Name You can set the name of DS. SNTP Enable the SNTP server. Time zone After you set the SNTP enable, select the time zone you located.
Page 40
IDS-5011F Series User’s Manual IP Configuration You must assign a valid IP address for DS before attached in your network environment. Your network administrator should provide you with the IP address and related settings. The IP address must be unique and within the network (otherwise, DS will not have a valid connection to the network).
Page 41
IDS-5011F Series User’s Manual The following table describes the labels in this screen. Label Description DHCP/BOOTP Obtain the IP address automatically from DHCP server. Static IP Address Assigning an IP address manually. Subnet Mask Set the subnet mask to communicate on the network.
Page 42
IDS-5011F Series User’s Manual Authentication You can set the password to prevent unauthorized access from network. Input the “Old password” and “New password” to change the password. Factory default is no password. Figure 5-21 Authentication ORing Industrial Networking Corp...
IDS-5011F Series User’s Manual 5.2.1.2 Port serial setting Serial configuration Figure 5-21 Serial configuration The following table describes the labels in this screen. Label Description Port Alias Remark the port to hint the connected device. Interface RS232 / RS422 / RS485(2-wires) / RS485(4-wires)
Page 44
IDS-5011F Series User’s Manual Parity No, Even, Odd, Mark, Space Flow Control No, XON/XOFF, RTS/CTS, DTR/DSR Force TX interval time is to specify the timeout when no data has been transmitted. Force TX Interval Time When the timeout is reached or TX buffer is full (4K Bytes), the queued data will be sent.
Page 45
IDS-5011F Series User’s Manual The following table describes the labels in this screen. Label Description Flush Data Buffer After: The received data will be queued in the buffer until all the delimiters are matched. When the buffer is full (4K Bytes) or after "flush S2E data buffer" timeout, the data will also be sent.
Page 46
IDS-5011F Series User’s Manual Service Mode – Virtual COM Mode In Virtual COM Mode, the driver establishes a transparent connection between host and serial device by mapping the Port of the serial server serial port to local COM port on the host computer. Virtual COM Mode also supports up to 5 simultaneous connections, so that multiple hosts can send or receive data by the same serial device at the same time.
Page 47
IDS-5011F Series User’s Manual The serial device will send TCP alive-check package in each defined time interval (Alive Check) to remote host to check the TCP connection. If the TCP connection is not Alive Check alive, the connection will be closed and the port will be freed. 0 indicate disable this function.
Page 48
IDS-5011F Series User’s Manual The following table describes the labels in this screen. Label Description TCP Server Port Set the port number for data transmission. When serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts.
Page 49
IDS-5011F Series User’s Manual Figure 5-24 TCP client mode The following table describes the labels in this screen. Label Description Destination Host Set the IP address of host and the port number of data port. . When serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts.
Page 50
IDS-5011F Series User’s Manual Connect on Any The TCP Client will build TCP connection once the connected serial device starts to send Character data. Table 5-18 TCP client mode Service Mode – UDP Client Mode Compared to TCP communication, UDP is faster and more efficient. In UDP...
IDS-5011F Series User’s Manual 5.2.1.3 Management Access IP Control Access IP Control Settings allow you to add or block the remote host IP addresses to prevent unauthorized access. If host’s IP address is in the accessible IP table, then the host will be allowed to access the DS. You can choose one of the following cases by setting the parameter.
Page 52
IDS-5011F Series User’s Manual SMTP/SNMP Conf Email Server configuration includes the mail server’s IP address or domain. If the authentication is required, specify your name and password. There are 4 Email addresses that you can specify to receive the notification.
Page 53
IDS-5011F Series User’s Manual System Event Conf. Specify the events that should be notified to the administrator. The events can be alarmed by E-mail, SNMP trap, or system log. Figure 5-28 SMTP / SNMP conf The following table describes the labels in this screen.
Page 54
IDS-5011F Series User’s Manual This refers to restart the computer without turning the power off. When performing a Software Reset (Warm warm start, DS will automatically send an E-mail, log information or SNMP trap after Start) reboot. When an unauthorized access from the Console or Web interface, a notification will be Login Failed sent.
IDS-5011F Series User’s Manual Eth1 link down When Eth1 link down, a notification will be sent and Fault LED will be lighted. Eth2 link down When Eth2 link down, a notification will be sent and Fault LED will be lighted.
IDS-5011F Series User’s Manual The following table describes the labels in this screen. Label Description Load default configuration except settings of Network. If you want load all factory default, Factory Default you should press “Reset” button about the five seconds on the device (Hardware restore).
IDS-5011F Series User’s Manual echnical Specifications Network Interface 1x 100Base-FX with SC connector Multi-Mode: Distance: 2km Wavelength: 1310nm Fiber Port Cable: 50/125 um , 62.5/125 um Single-Mode: Distance: 30km Wavelength: 1310nm Cable: 9/125 um ICMP, IP, TCP, UDP, DHCP, BOOTP, ARP/RARP, DNS, SNMP...
Page 58
IDS-5011F Series User’s Manual Flow control XON/XOFF, RTS/CTS, DTR/DSR Serial Line Protection Built-in15KV ESD protection PWR (1)(2) / Ready: 1) Red On: Power is on and booting up. Red Blinking: Indicates an IP conflict, or DHCP or BOOTP server did not respond properly.
Page 59
IDS-5011F Series User’s Manual TCP Alive Check Timeout Inactivity Timeout Delimiter for Data Packing Force TX Timeout for Data Packing Multiple Link 5 Hosts simultaneous connection: Virtual Com / TCP server / TCP Client / UDP VCOM Driver Windows NT/2000/XP/2003/VISTA...