Marantz SR5010/U1B Service Manual page 44

Av surround receiver
Table of Contents

Advertisement

3.5. Protection History Display Mode
3.5.1. Actions
This mode enables the unit to record and display the event when the THERMAL, ASO or DC protection is activated.
If protections have been activated multiple times, the latest protection operation is recorded.
3.5.2. Starting up
While holding down buttons "ZONE2 SOURCE" and "STATUS" simultaneously, press the power button to turn on the
power.
Select the "2. PROTECTION" using the "TUNER PRESET CH +/-" button, then press the "STATUS" button to confirm.
3.5.3. Protection information and displays
· Press the "STATUS" button in Protection History Display Mode.
· The protection history can be checked.
(a) If no protections has occurred.
L1
P R O T E C T
FLD
L2
H I S T O R Y
L3
: N O
(b) ASO (if the last protection is ASO)
FLD
L3
: A S O
Cause : A short circuit occurred between the speaker terminals, or speakers with an impedance outside the rating were
connected.
DC output of the power amplifier is abnormal.
Note : A short circuit occurred between the speaker terminals, or speakers with an impedance outside the rating were
connected.
If the power is turned on in the abnormal state, protection is activated after around 6 seconds and the power is turned off.
(c) DC (if the last protection is DC)
FLD
L3
: D C
Cause : A short circuit occurred between the speaker terminals, or speakers with an impedance outside the rating were
connected.
DC output of the power amplifier is abnormal.
Note : A short circuit occurred between the speaker terminals, or speakers with an impedance outside the rating were
connected.
If the power is turned on in the abnormal state, protection is activated after around 6 seconds and the power is turned off.
(d) THERMAL (if the last protection is THERMAL(A) or THERMAL(B) or THERMAL(E))
FLD
L3
: T H M
FLD
L3
: T H M
FLD
L3
: T H M
Cause : Abnormal heat sink temperature.
If the power is turned on in the abnormal state, protection is activated after around 2 minutes and the power is turned off.
(e) Case of CURRENT (when the last protection incident is CURRENT protection)
FLD
L3
: C U R R E N T
Caution : These protections may also be activated due to other factors such as disconnection of connectors or operations
around the microcomputer.
After viewing the above protection history, press the "STATUS" button to return to the normal display.
A
B
E
44

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr5010/n1bSr5010/n1sgSr5010/k1b

Table of Contents