Ingersoll-Rand Schlage AD-400 User Manual
Ingersoll-Rand Schlage AD-400 User Manual

Ingersoll-Rand Schlage AD-400 User Manual

Networked wireless lock
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

23980030
AD-400
GUIA DO USUÁRIO DA FECHADURA
SEM FIO EM REDE
INSTRUÇÕES PARA FECHADURAS SEM FIO EM REDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Schlage AD-400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ingersoll-Rand Schlage AD-400

  • Page 1 23980030 AD-400 GUIA DO USUÁRIO DA FECHADURA SEM FIO EM REDE INSTRUÇÕES PARA FECHADURAS SEM FIO EM REDE...
  • Page 2: Table Of Contents

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 CONTEÚDO Visão Geral ............................ 3 Introdução............................4 Software Utilitário Schlage (Sus) ....................4 Botão Interno De Saida Opcional (Ipb) ..................4 Gerenciamento De Usuário ......................4 Modo De Acesso De Construção ....................5 Criar a Credencial de Construção Master - Fechaduras com leitores de cartões .....
  • Page 3: Visão Geral

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 VISÃO GERAL A fechadura AD-400 da Schlage é um controle de acesso (WAPM) de arquitetura aberta sem fio projetado para interface com painéis de terceiros através de um PIM400. • O AD-400 se comunica com o PIM400 via RF (rádio freqüência). •...
  • Page 4: Introdução

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 INTRODUÇÃO Siga estes passos ao configurar uma nova fechadura. 1. Instale a fechadura. Veja o guia de instalação que vem com a fechadura ou visite www.schlage.com/ support, para obter mais informações. 2.
  • Page 5: Modo De Acesso De Construção

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 MODO DE ACESSO DE CONSTRUÇÃO A configuração deste modo é usado para permitir o acesso antes DICAS que a fechadura seja conectada a um PIM400, e / ou para fins de Use a mesma Credencial teste antes de conectar.
  • Page 6: Conexão Com O Pim400

    Para um leitor de teclado, pressione a tecla “#”. 6. Continue a pressionar a maçaneta ou barra antipãnico até que o botão Schlage AD-400 comece a piscar em verde, indicando que o processo de conexaõ já começou (aproximadamente 8 segundos).
  • Page 7: Teste De Funcionamento Da Fechadura

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 TESTE DE FUNCIONAMENTO DA FECHADURA Se você encontrar problemas ao executar qualquer um dos testes seguintes, reveja as instruções de instalação e deste guia e corrija quaisquer problemas. Teste Mecânico 1.
  • Page 8: Restaurar Para Ajustes Padrão De Fábrica

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 RESTAURAR PARA AJUSTES PADRÃO DE FÁBRICA Todas as informações na fechadura serão eliminadas e restaurados para os padrões de fábrica! Nível 1 Restaurar Padrão de Fábrica Î ÎNívelÎ1ÎrestaurarÎpadrãoÎdeÎfábricaÎiráÎapagarÎasÎconfiguraçõesÎeÎdefiniçõesÎnoÎcontroladorÎ principalÎnaÎfechadura. Î ÎNívelÎ1ÎrestaurarÎpadrãoÎdeÎfábricaÎnãoÎrestauraráÎconfiguraçõesÎeÎdefiniçõesÎnoÎleitor.
  • Page 9: Propriedades De Comunicação

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 PROPRIEDADES DE COMUNICAÇÃO Propriedade Descrição Pulsação Quando a fechadura estiver ociosa, a pulsação é uma breve comunicação da fechadura com o PIM400. A pulsação permite que uma fechadura ociosa verifique as mensagens do PIM400. Por padrão, isso ocorre a cada 10 minutos, mas pode ser ajustada na faixa de 15 segundos para muitas horas.
  • Page 10: Pilhas

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 PILHAS Instalar ou substituir pilhas Aproximadamente um mês antes do final da vida da pilha, um sinal de pilha fraca é indicado no PIM400 e um sinal de problema será enviado para o painel de controle de acesso. 1.
  • Page 11 Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 Modo Descrição Deixar como está Fechadura permanece no estado atual até que as pilhas sejam (padrão) substituídas. Falhou Desbloqueado Fechadura destrava e permanece destravada até que as pilhas sejam substituídas. Falhou Bloqueado Fechadura trava e permanece travada até...
  • Page 12: Fornecimento De Energia Externo

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 FORNECIMENTO DE ENERGIA EXTERNO O AD-400 pode ser conectado à fonte de energia externa usando uma fonte de alimentação UL294 listada capaz de fornecer pelo menos 250 mA @ 12 ou 24 VDC. –...
  • Page 13: Solução De Problemas

    Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 SOLUÇÃO DE PROBLEMAS Problema Possível causa Solução O sinal sonoro da O leitor não está Verifique se o leitor está totalmente fechadura não emite corretamente encaixado no encaixado no brasão frontal. som e o teclado brasão frontal.
  • Page 14 Guia Do Usuário Da Fechadura Sem Fio Em Rede AD-400 Problema Possível causa Solução O leitor não está O orifício do cabo Verifique se o orifício do cabo flexível não funcionando. flexível pode estar sendo está sendo comprimido. comprimido. O cartão inteligente Mode o formato do Smart card usando o não está...
  • Page 15 AD-400 NETWORKED WIRELESS LOCK USER GUIDE INSTRUCTIONS FOR ADAPTABLE SERIES NETWORKED WIRELESS LOCKS Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support.
  • Page 16 AD-400 Networked Wireless Lock User Guide CONTENTS Overview ............................3 Getting Started ..........................4 Schlage Utility Software (SUS) ...................... 4 Optional Inside Push Button (IPB) ....................5 User Management ......................... 5 Construction Access Mode ......................6 Create the Master Construction Credential - Locks with Card Readers ........6 Add Construction Access Mode User Credentials - Locks with Card Readers ......
  • Page 17: Overview

    AD-400 Networked Wireless Lock User Guide OVERVIEW The Schlage AD-400 is an open architecture Wireless Access Point Module (WAPM) designed to interface with third-party panels through a PIM400. • The AD-400 communicates with the PIM400 via RF (radio frequency). • AD-400 communicates with the PIM400 via RF and may be linked only to a PIM400.
  • Page 18: Getting Started

    AD-400 Networked Wireless Lock User Guide GETTING STARTED Follow these steps when setting up a new lock. 1. Install the lock. See the installation guide that came with the lock, or visit www.schlage.com/support, for more information. 2. Make sure the batteries are installed properly. See Batteries on page 11 for more information. 3.
  • Page 19: Optional Inside Push Button (Ipb)

    AD-400 Networked Wireless Lock User Guide OPTIONAL INSIDE PUSH BUTTON (IPB) • The inside push button (IPB) state is communicated to the access control panel by the PIM400-485. The manner in which the network access control software utilizes this communication is configured at the host. The IPB may be used to communicate a lock/unlock request or be completely ignored by the network software.
  • Page 20: Construction Access Mode

    AD-400 Networked Wireless Lock User Guide CONSTRUCTION ACCESS MODE Construction Access Mode is used to allow access before the lock is TIPS linked to a PIM400, and/or for testing purposes before linking. Use the same Master Construction Access Mode requires a credential other than a PIN. Construction Credential for all the locks in the facility.
  • Page 21: Link To A Pim400

    AD-400 Networked Wireless Lock User Guide LINK TO A PIM400 Î ÎOnlyÎoneÎAD-400ÎcanÎbeÎlinkedÎatÎoneÎtime.ÎEnsureÎthatÎnoÎotherÎ PIM400ÎunitsÎareÎinÎlinkÎmodeÎduringÎthisÎprocess. During linking, the Schlage 1. Make sure that the batteries are installed in the AD-400. See button will blink red and Batteries on page 11 for more information. green.
  • Page 22: Test Lock Operation

    AD-400 Networked Wireless Lock User Guide TEST LOCK OPERATION If you encounter problems while performing any of the following tests, review the installation instructions and this guide and correct any problems. Mechanical Test 1. Rotate the inside lever. Operation should be smooth, and the latch should retract. 2.
  • Page 23: Reset To Factory Default Settings

    AD-400 Networked Wireless Lock User Guide RESET TO FACTORY DEFAULT SETTINGS All information in the lock will be deleted and reset to factory defaults! Level 1 Factory Default Reset Î ÎLevelÎ1ÎfactoryÎdefaultÎresetÎwillÎdeleteÎconfigurationsÎandÎsettingsÎinÎtheÎmainÎcontrollerÎinÎtheÎlock. ÎLevelÎ1ÎfactoryÎdefaultÎresetÎwillÎnotÎresetÎconfigurationsÎandÎsettingsÎinÎtheÎreader. Î 1. Remove the top inside cover. 2. Press and hold the Schlage button until two (2) beeps sound (10 seconds). 3.
  • Page 24: Communication Properties

    AD-400 Networked Wireless Lock User Guide COMMUNICATION PROPERTIES Property Description Heartbeat When the lock is idle, the heartbeat is a brief communication from the lock to the PIM400. The heartbeat allows an idle lock to check for messages from the PIM400. By default, this occurs every 10 minutes, but can be adjusted in the range of 15 seconds to many hours.
  • Page 25: Batteries

    AD-400 Networked Wireless Lock User Guide BATTERIES Installing or Replacing Batteries Approximately one month prior to the end of the battery life, a Low Battery Trouble signal is indicated at the PIM400 and a Trouble signal will be sent to the access control panel. 1.
  • Page 26: External Power Supply

    AD-400 Networked Wireless Lock User Guide EXTERNAL POWER SUPPLY The AD-400 may be connected to external power using a UL294 listed power supply capable of sourcing at least 250 mA @ 12 or 24 VDC. – Polarity Required When externally powered, the lock will always fail as-is if power is lost. LED AND BEEP REFERENCE The beep indicator may be enabled or disabled using the SUS.
  • Page 27: Troubleshooting

    AD-400 Networked Wireless Lock User Guide TROUBLESHOOTING Problem Possible Cause Solution The lock beeper does The reader may not be Check that the reader is fully seated into not sound and the properly seated into the front the front escutcheon. keypad does not light escutcheon.
  • Page 28 AD-400 Networked Wireless Lock User Guide Problem Possible Cause Solution The reader is not The through hole ribbon Check that the through hole ribbon cable working. cable may be pinched. is not pinched. The Smart card is not The Smart card default of Change the Smart card format using the reading.

Table of Contents