Rheem HBT200 Installation Instructions Manual page 19

Collectors with copper waterways, conetite connections for use in direct systems using uncoated dr brass conetite fittings
Table of Contents

Advertisement

8.
Connector: Fit a connector (10) to the inlet of the solar collector array.
Refer to
"Coupling Cold and Hot Pipes to Collector – Conetite Fittings"
page 22.
9.
Sensor Connector: Fit a sensor connector (4) (with hot sensor port) to
the outlet of the solar collector array.
Refer to
"Coupling Cold and Hot Pipes to Collector – Conetite Fittings"
page 22.
10. End Plug (Collector Bung): Fit the end plugs (5) (collector bung)
assemblies to the two remaining solar collector connections.
Refer to
"End Plug (Collector Bung) Assembly – Conetite Fittings"
page 22.
11. Solar Cold and Solar Hot Pipes: Install the solar cold pipe from the solar
storage tank to the solar collectors (17) and the solar hot pipe from the
solar collectors (17) to the solar storage tank.
The solar hot and solar cold pipes should be a minimum DN15, but sized
to suit the installation for a direct open circuit system. Refer to
Lengths"
on page 11.
The solar hot and solar cold pipes must have a continuous fall from the
solar collectors to the solar storage tank. Horizontal runs of pipe work are
acceptable and may be installed for a direct open circuit system.
The full length of the solar hot and solar cold pipes must be insulated. The
insulation must be capable of withstanding the temperatures generated by
the solar collectors under stagnation conditions.
Warning: Plumber – Be Aware: It is important you refer to
Plumber – Be Aware"
relating to the installation of the solar hot and solar cold pipes.
Refer also to
Work Roughing In Dimensions"
on page 12 for further and important information
installation diagrams on pages
on page 26.
ROOF ASSEMBLY OF SOLAR COLLECTORS
32, 33
19
"Pipe
"Warning:
and
34 and to
"Pipe
on
on
on