SOLAR COLLECTOR LOCATION
Maximum Height to Collectors – Direct Open Circuit
The maximum height of a solar installation, from the solar controller (circulator)
to the top of the solar collectors, is determined by the maximum recommended
total pipe length for the system and the water supply pressure.
The maximum recommended total pipe length of the solar circuit should not be
exceeded and a minimum water supply pressure of 200 kPa should be
available at the inlet to the system, otherwise the system performance may be
reduced or the solar circuit may not be purged of air during the commissioning
of the system.
Direct Open Circuit Solar
Pipe Work Installation Requirements
14