PREPARING FOR
FEATURES
I
INSTALLATION
Plasma-proof design
I
The IR-SMR Receiver cable must reach the
Rejects interference from flat panel displays,
proposed location of the IR Connecting Block. If
CFL lighting or indirect sunlight
I
not, use Category 5 cable to extend the length.
Works with practicality all remotes
Mark the cable with a Wire label, describing
I
where the cable originates from, rather than
Extended receiving range
I
where it will terminate. Make sure the mounting
Green talkback LED indicates when A/V
surface is cleaned and degreased before
system is on
I
installation.
Blue talkback LED confirms reception of
IR signals
TOOLS REQUIRED
I
Installation friendly design:
1/8" Slotted screwdriver
I
I
10' feet of connecting wire included
Wire stripper
I
I
Reliable adhesive backing
Wire labels
PACKAGE CONTENTS
INSTALLATION
I
IR-SMR Receiver x 1
1. Determine a mounting location for the IR-SMR.
I
10 Feet of Connecting Wire x 1
2. Make sure the mounting surface is clean.
I
Adhesive-Backed Strip for Mounting x 1
3. Remove the protective coating from the self-
adhesive tape and attach the IR-SMR to the
mounting surface.
PRODUCT OVERVIEW
4. Run the IR-SMR cable. Label the cable for
future reference.
5. Strip 1/4" of insulation from the end of each
CAT5 wire.
6. Locate the IR Connecting Block Snap and Lock
Connectors and remove them if they are
Figure 1 : Wiring legend
plugged in.
1
7. Use a small flathead screwdriver or your
thumb to raise the locking tabs, exposing the
holes on the connectors.
8. Insert each wire into the appropriate hole and
snap down the locking tabs. Figure 2.
9. Insert the smooth
side of the
connector plug into
the smooth side of
the IR Connecting
Block socket.
See installation diagram.
Installation Note:
The talkback LED can be disabled if it continues
to flicker or visual feedback is not desired.
Discrete on and off IR commands are available
on the JobSite Technical support website for
disabling the feedback LED. The address is:
www.jobsitesystems.com/technicalsupport/
Using the IR-SMR with a
JobSite M-4KP Keypad:
The IR-SMR is fully compatible with the JobSite
M-4KP Keypad: follow the wiring instructions in
Figure 3
2
3
INSTALLATION DIAGRAM
IR-SMR
IR-CB2
Figure 2
Stereo Receiver
JobSite
IR-E1
Emitter
12V DC Power Supply
(Not Supplied) plugged
into the Switched Outlet
12V DC Power Supply
Plugged into an
Unswitched AC Outlet
Powers the System
Figure 3 : Suggested wiring of WMR to an RJ45
connector for connection to a JobSite M-4KP keypad.
4
I
OPERATION
Observe the IR-SMR's LED while performing all
the tests. It is possible to have interference from
Operation of the IR-SMR is simple. Stand within
more than one source.
the operational range of your IR-SMR. Aim your
hand-held remote at the IR-SMR and press the
Eliminating optical feedback
button for the desired command. Your IR
Optical Feedback Loop
command is instantly repeated to your A/V
If you have an IR receiver in the same room as a
equipment.
emitter, and you have some low-level noise or
Green "Power Status" LED
interference, an optical feedback loop can occur
which will interfere with proper operation.
When the IR-SMR is correctly connected as
Symptoms can include: poor range, intermittent
shown in Installation Diagram, the Green LED
operation or no operation.
will stay lit as long as the preamp/receiver is on.
Solution:
When your preamp/receiver is off, the LED will
stay off.
Replace the IR-E1HO "flooding Emitter" with IR-E1
or IR-E2 Emitters and cover all emitters with the
Blue "Talkback" LED
supplied IR Blocking Covers.
The blue "talkback" LED on the IR-SMR visually
Identifying the type of interference
confirms the reception of an IR command.
The "talkback" LED on the front of the IR-SMR is
a useful trouble-shooting aid.
TROUBLESHOOTING
The LED should light blue only when a remote
command is being received. However, if the LED
1. Test the remote control(s) by operating the A/V
on the IR-SMR "flickers", and the IR-SMR functions
equipment directly. Replace the batteries if
normally, there is no cause for concern.
needed.
If the IR-SMR does not work, and the LED
2. Double-check the cable connections on all
does not light at all:
IR-SMRs and on the Connecting Block. Look
for open, shorted or reversed wires.
Test the remote control(s) by operating the A/V
equipment directly. Replace the batteries if needed.
3. Test for interference from the following sources:
I
Double-check the wiring connections of the IR-
Neon or halogen lights in the room.
SMR, at the IR Connecting Block. Consult your IR
I
Connecting Block's manual for more detail.
Light dimmers, beginning with those closest to
the IR-SMR.
5
(Over Please)
6

Advertisement

loading

Summary of Contents for Jobsite IR-SMR

  • Page 1 The blue “talkback” LED on the IR-SMR visually Identifying the type of interference confirms the reception of an IR command. The “talkback” LED on the front of the IR-SMR is a useful trouble-shooting aid. TROUBLESHOOTING The LED should light blue only when a remote command is being received.
  • Page 2 Custom and Niles are registered trademarks of Niles Audio interference. Which solution is best for you Corporation and the JobSite Logo is a trademark of Niles Audio depends on your situation. If you require further Corporation. All other trademarks are the property of their respec- tive owners.