DEFINITION
Wood burning stove designed for installation close to a wall, and
which can be moved with no need for additional work. The
connection to the flue pipe is made through stainless steel or
vitreous enamel pipes conforming to standard NFD 35-302. The
connection must be made to an individual flue pipe.
SAFETY CLEARANCE
Comply with the safety clearances indicated between the wall and
the sides or the back of the appliance. If the wall is non-
combustible, then the safety clearance does not apply. Regardless
of the orientation of the stove, there must be a clearance of 2 m
between the glass and the wall or any flammable material.
PREPARATION OF THE STOVE
Unpack the appliance: remove the screws securing it to the pallet.
Install the stove on a floor with sufficient load-bearing capacity. If
the floor cannot support the load, then measures should first be
taken (for example, the installation of a load distribution plate).
Position the stove in its definitive location and level it. For ease of
maintenance, it is recommended to lay tiles or some other type of
covering in the load-bearing area.
MOUNTING THE BAFFLE PLATE
The cast iron baffle plate is an important element for the improved
efficiency of the appliance, facilitating the recovery of the soot
during sweeping. The baffle plate is installed when the appliance is
delivered. Before operating the wood burning stove, the baffle
plate should be installed and removed a number of times in order
to become familiar with its operation. The baffle plate comprises
two parts: to dismount it, you need to remove part (1) and then
part (2).
Baffle plate removal procedure:
1. Remove the side vermiculite panels.
2. Remove baffle plate No. 1.
- Lift the baffle, tilt it and take it out at an angle through the door
opening.
3. Remove baffle plate No. 2.
- Lift the baffle, tilt it and take it out at an angle through the door
opening.
To mount the plates again, proceed in reverse order to the above.
THIRD BAFFLE PLATE
For the annual chimney sweeping, first remove the two baffle
plates as explained above and then remove the third one as
indicated below:
- remove the 2 screws and take the baffle plate out.
To mount the baffle plates again, proceed in the reverse order.
CHANGING FROM A TOP TO REAR OUTLET
At the time of delivery, the Ø 150 collar is mounted on the top
outlet of the stove. Depending on the flue type, the collar can also
be installed on the rear outlet of the appliance. To reverse the flue
orientation:
1. Remove the 3 baffle plates.
2. Unscrew the 2 screws securing the collar, located on the top of
the appliance (Allen key No. 4).
3. Remove the screw securing the damper rod inside the stove
box (Allen key No. 10).
4. Check that the seals under the damper and collar are correctly
in place when reassembling and mount these 2 items in reverse
order (the rod is only used to reassemble the damper). Use the 2
holes located at the rear of the appliance to reassemble the collar.
5. Reassemble the baffle plates.
6. Connect the stove through the rear outlet.