HIKVISION Module Door Station Quick Start Manual
HIKVISION Module Door Station Quick Start Manual

HIKVISION Module Door Station Quick Start Manual

Video intercom
Hide thumbs Also See for Module Door Station:

Advertisement

Quick Links

Module Door Station
Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION Module Door Station

  • Page 1 Module Door Station Quick Start Guide...
  • Page 2 Trademarks and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applications for the same by Hikvision and/or its affiliates. Other trademarks mentioned in this manual are the properties of their respective owners. No right of license is given to use such trademarks without express permission.
  • Page 3 SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.
  • Page 4 Module Door Station Quick Start Guide Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or Danger could result in death or serious injury.
  • Page 5: Table Of Contents

    Module Door Station Quick Start Guide Contents 1 Appearance ....................1 2 Terminal and Wiring ................... 5 2.1 Terminal Description ..................5 2.2 Door Lock Wiring ....................7 2.3 Door Magnetic Wiring ..................7 2.4 Exit Button Wiring ..................... 8 3 Installation ....................
  • Page 6 Module Door Station Quick Start Guide 4.4.1 Dial via Main Unit ................... 47 4.4.2 Dial via Nametag Module ............... 48...
  • Page 7: Appearance

    Module Door Station Quick Start Guide 1 Appearance Main Unit Figure 1-1 Main Unit Appearance Table 1-1 Appearance Description Description Microphone Low Illumination IR Supplement Light Built-in Camera Loudspeaker Call Button Nametag TAMPER Network Interface Module-​ C onnecting Interface (output)
  • Page 8 Module Door Station Quick Start Guide Note Nametag area supports insert customized name card. The suggested • card size is: 58 (L) x 11.7(W) mm. The module connecting interface is used to connect other function • module, such as nametag module, keypad module, card reader module, etc.
  • Page 9 Module Door Station Quick Start Guide Keypad Module Figure 1-3 Keypad Module Appearance Table 1-3 Appearance Description Description Button Module-​ C onnecting Interface (output) Module-​ C onnecting Interface (input) Debug Port Card Reader Module Figure 1-4 Card Reader Module...
  • Page 10 Module Door Station Quick Start Guide Table 1-4 Appearance Description Description Card Reading Area Module-​ c onnecting Interface (output) Module-​ c onnecting Interface(input) Debug Port...
  • Page 11: Terminal And Wiring

    Module Door Station Quick Start Guide 2 Terminal and Wiring 2.1 Terminal Description Main Unit Terminals Figure 2-1 Main Unit Terminals Table 2-1 Descriptions of Terminals and Interfaces Interface Description Door Lock Relay Output (NC) Door Lock Relay Output (NO)
  • Page 12 Module Door Station Quick Start Guide Interface Description AIN4 For the access of Exit Button 2 485- Module-​ c onnecting Interface 485+ 12 V OUT PoE Network Interface(Supports IEEE 802.3af/at-Compliant Devices) Sub Module Terminal Figure 2-2 Sub Module Terminal Table 2-2 Description...
  • Page 13: Door Lock Wiring

    Module Door Station Quick Start Guide Interface Description 12V OUT 2.2 Door Lock Wiring Figure 2-3 Door Lock Wiring Note Terminal NC1/COM is set as default for accessing magnetic lock/electric bolt; • terminal NO2/COM is set as default for accessing electric strike.
  • Page 14: Exit Button Wiring

    Module Door Station Quick Start Guide Figure 2-4 Door Magnetic Wiring Note AIN1 and AIN2 are defaulted to connect door magnetic. Door magnetic connected to AIN1 detects status of the lock that connected to NC1/NO1; Door magnetic connected to AIN2 detects the status of the lock connected to NC2/NO2.
  • Page 15 Module Door Station Quick Start Guide Note AIN3 and AIN4 are set as default for connecting exit button. Exit button connected to AIN3 opens the lock connected to NC1/NO1; Exit button connected to AIN4 controls the lock that connected to NC2/NO2.
  • Page 16: Installation

    Module Door Station Quick Start Guide 3 Installation Note Make sure the device in the package is in good condition and all the assembly • parts are included. Sub module must work along with the main unit. • Set the sub module address before start the installation steps.
  • Page 17: Two-Module Installation

    Module Door Station Quick Start Guide Note Digit 1, 2, 3, 4 are used to coding the sub module address; Digit 5, 6, 7 are • reserved; Digit 8 is a resistance (120Ω) is you set it as on. Valid sub module address range is 1 to 8. The No. should be unique for sub •...
  • Page 18 Module Door Station Quick Start Guide Before You Start Figure 3-2 Mounting Frame Note The dimension of two-module mounting frame is: 219(W)×107 (H)×32.7(D) mm. • The dimensions above are for reference only. The actual size can be slightly • different from the theoretical dimension.
  • Page 19 Module Door Station Quick Start Guide Figure 3-3 Chisel Screw Holes 3. Remove the sticker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts. Figure 3-4 Fix the Mounting Frame 5.
  • Page 20 Module Door Station Quick Start Guide Figure 3-5 Placement of Lines 6. Connect the cables. 1) Connect the cables and module-connecting line to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line to the input interface of the sub module.
  • Page 21 Module Door Station Quick Start Guide Figure 3-6 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. Main unit must be placed in the top grid. Figure 3-7 Insert the Modules 8. Use the hexagon wrench in the package fix the cover onto the frame.
  • Page 22: Two-Module Flush Mounting

    Module Door Station Quick Start Guide Figure 3-8 Fix the Cover 3.2.2 Two-Module Flush Mounting Before You Start Figure 3-9 Gang Box...
  • Page 23 Module Door Station Quick Start Guide Note The dimension of one-module gang box is: 237(W)×134(H)×56(D) mm. • The dimensions above are for reference only. The actual size can be slightly • different from the theoretical dimension. Steps 1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 220(W)×108(H)×45.5(D) mm.
  • Page 24 Module Door Station Quick Start Guide Figure 3-11 Mark the Screw Holes 4. Chisel 4 holes with drill align to marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45 (depth) mm.
  • Page 25 Module Door Station Quick Start Guide Figure 3-13 Remove the Mounting Ears 7. Connect wires and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
  • Page 26: Three-Module Installation

    Module Door Station Quick Start Guide Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 refers to the module-connecting line in the accessory package. 8. Use the hexagon wrench in the package fix the cover.
  • Page 27 Module Door Station Quick Start Guide Note The dimension of two-module mounting frame is: 320.8 (W) × 107 (H) × 32.7(D) • The dimensions above are for reference only. The actual size can be slightly • different from the theoretical dimension.
  • Page 28 Module Door Station Quick Start Guide Figure 3-18 Fix the Mounting Frame Note The mounting frame should be placed exactly as below for this step. The tamper plate should be at the low right of the first grid.
  • Page 29 Module Door Station Quick Start Guide Figure 3-19 Mounting Frame 5. Thread the module-connecting lines across the thread holes of the frame. Pass the main unit connecting lines across the thread hole to the top grid.
  • Page 30 Module Door Station Quick Start Guide Figure 3-20 Placement of Lines 6. Connect the cables. 1) Connect the cables and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
  • Page 31 Module Door Station Quick Start Guide Figure 3-21 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. Main unit must be placed in the top grid. Figure 3-22 Insert the Modules into the Frame...
  • Page 32: Three-Module Flush Mounting

    Module Door Station Quick Start Guide 8. Use the hexagon wrench in the package fix the cover onto the frame. Figure 3-23 Fix the Cover 3.3.2 Three-Module Flush Mounting...
  • Page 33 Module Door Station Quick Start Guide Before You Start Figure 3-24 Gang Box Note The dimension of one-module gang box is: 338.8(W)×134(H)×56(D) mm. • The dimensions above are for reference only. The actual size can be slightly • different from the theoretical dimension.
  • Page 34 Module Door Station Quick Start Guide Figure 3-25 Cave the Installation Hole 2. Remove the plastic sheet of the cable entry which will be used. 3. Insert the gang box into the hole and pull out the cables through the cable entry.
  • Page 35 Module Door Station Quick Start Guide Figure 3-27 Fix the Gang Box 6. Fill and level up the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry. Figure 3-28 Remove the Mounting Ears 7.
  • Page 36: More-Than-Three Module Installation

    Module Door Station Quick Start Guide Figure 3-29 Connect Wires and Insert Modules Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 and Cable 3 refer to the module-connecting line in the accessory package.
  • Page 37 Module Door Station Quick Start Guide Before You Start Figure 3-31 Mounting Frame Note It takes two three-module mounting frames. The dimension of three-module • mounting frame is: 320.8(W)×107 (H)×32.7(D) mm. The dimensions above are for reference only. The actual size can be slightly •...
  • Page 38 Module Door Station Quick Start Guide Figure 3-32 Chisel Screw Holes 4. Remove the stickers and insert the expansion sleeves into the screw holes. 5. Thread the module-connecting line (400 mm) and grounding line across the thread hole of both frames.
  • Page 39 Module Door Station Quick Start Guide Note There are 6 module-connecting lines in the package: 190 mm × 4 and 400 • mm × 2. Take the 400 mm one for this step. • The green-yellow line in the package is for grounding.
  • Page 40 Module Door Station Quick Start Guide 1) Connect the cables and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line1 to the input interface of the sub module.
  • Page 41 Module Door Station Quick Start Guide Figure 3-37 Insert the Modules 10. Pull the grounding line out and fixed its two end to the screw on the cover. Figure 3-38 Connect the Grounding Line to the Cover 11. Use the hexagon wrench in the package fix the cover onto the frame.
  • Page 42: More-Than-Three Module Flush Mounting

    Module Door Station Quick Start Guide Figure 3-39 Fix the Cover 3.4.2 More-Than-Three Module Flush Mounting...
  • Page 43 Module Door Station Quick Start Guide Before You Start Figure 3-40 Gang Box Note It takes two three-module gang boxes. The dimension of the gang box is: 338.8 • (W) × 134 (H) × 56 (D) mm. The dimensions above are for reference only. The actual size can be slightly •...
  • Page 44 Module Door Station Quick Start Guide Steps 1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8 (W) × 315 (H) × 45.5 (D) mm. The suggested length of cables left outside is 270 mm.
  • Page 45 Module Door Station Quick Start Guide 4. Remove the plastic sheets on the side of the gang boxes (shown as 1 and 2) below: Figure 3-43 Remove the Plastic Sheets 5. Insert the gang boxes into the hole and pull out the cables through the cable entry.
  • Page 46 Module Door Station Quick Start Guide Figure 3-45 Fix the Gang Boxes 8. Fill and level up the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry. Pass the grounding line through the cable entries.
  • Page 47 Module Door Station Quick Start Guide 2) Connect the other end of Cable 2 to the input interface of Sub Module 1. Connect one end of Cable 3 to the output interface of Sub Module 1 and insert it into the middle grid of the left gang box.
  • Page 48 Module Door Station Quick Start Guide Note Cable 2,3,5 and 6 are the module-connecting lines (190 mm) in the package. • Cable 4 is the module-connecting line (400 mm) in the package. • Main unit must be put in the top grid.
  • Page 49 Module Door Station Quick Start Guide Figure 3-50 Fix the Cover...
  • Page 50: Remote Operation

    Module Door Station Quick Start Guide 4 Remote Operation The Video Intercom module provides remote control and configuration on video intercom products via the iVMS-4200 client software. 4.1 Activate Device You can only configure and operate the door station after creating a password for the device activation.
  • Page 51: Edit Network Parameters

    Module Door Station Quick Start Guide Note We highly recommend you to create a strong password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 52: Add Device

    Module Door Station Quick Start Guide Figure 4-4 Modify Parameters Note The default port No. is 8000. • The default IP address of the door station is 192.0.0.65. • After editing the network parameters of device, you should add the devices •...
  • Page 53: Call Resident

    Module Door Station Quick Start Guide Figure 4-6 Add to the Client 4.4 Call Resident You can call residents via the door station. 4.4.1 Dial via Main Unit Steps 1. Select device, click Remote Configuration. Figure 4-7 Remote Configuration 2. Click Intercom → Dial to enter the dial settings page.
  • Page 54 Module Door Station Quick Start Guide Figure 4-8 Dial Settings Page (Private SIP) Figure 4-9 Dial Settings Page (Standard SIP) 3. Enter the Room No. of the indoor station which the main unit connected to. You can call corresponding resident by press the call button on the main unit.
  • Page 55 Module Door Station Quick Start Guide Figure 4-11 Sub Module Configuration Page 3. Select Nametag Module to pop up the configuration window. 4. Enter Room No. for each call button, and click Save.
  • Page 56 UD13690B...