Page 1
PG-F ECHNICAL RACTICE FRE-860 FRE-868 PG-Flex Remote Terminal Enclosures PG-Flex Model List No. Part No. CLEI Code TELEPHONE COMPANY PROPERTY FRE-860 150-2360-01 VAMRMS0A TELEPHONE COMPANY PROPERTY 150-2360-11 VAMRRS0A FRE-865 150-2365-01 VAMRNS0A PairGain PairGain FRE-868 FRE-860 MADE IN USA MADE IN USA...
Page 2
Information furnished by PairGain Technologies is believed to be accurate and reliable. However, no responsibility is assumed by PairGain Technologies for its use, nor for any infringement of patents or other rights of third parties which may result from its use.
Page 3
• Unpack each container and visually inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to PairGain. Order replacement equipment, if necessary. •...
® ® The PairGain PG-Flex FRE-860, FRE-865, FRE-867, and FRE-868 Remote Terminal (RT) Enclosures (see Figure 1) conveniently mount RT line units (LU) and channel units (CU). The RT Enclosures provide termination points for subscriber circuits, HDSL, auxiliary power, and metallic bypass pairs.
Page 6
Overview 363-860-100-02, Revision 02 Table 1. FRE-860, 865, 867, and FRE-868 Features RTE-860 RTE-865 RTE-867 RTE-868 RT Enclosures L1A L1B Outdoor Wall or Pole Mount Installation Outdoor Pedestal Mount (Marconi UP 10900) Type Indoor Wall Mount Number of 24 Channel...
Page 7
30 lbs., 34 lbs., 56 lbs., 32 lbs., 11.1 Kg 12.6 Kg 20.9 Kg 11.9 Kg (including cables) (including cables) Cable Length 35 ft. (10.6 m) 35 ft. (10.6 m) Subscriber Lines FRE-860, FRE-865, FRE-867, and FRE-868 March 28, 2000...
The COLU, unless previously disabled by means of Craft provisioning, periodically attempts to power up the RT Enclosure by applying +/-130 Vdc to the HDSL pairs. EQUIRED OOLS AND QUIPMENT • 216 Tool (can wrench) • flat-head screwdriver • insulated-handled needlenose pliers March 28, 2000 FRE-860, FRE-865, FRE-867, and FRE-868...
FRE-860 RT E NSTALLING THE NCLOSURE The FRE-860 RT Enclosure has external mounting flanges with tapped holes for #10-machine screws for pedestal mounting Remove horizontal crossbars from the UP10900 pedestal prior to mounting the FRE-860. Attach the RT Enclosure to the pedestal frame, using the mounting flanges (see Figure 2).
Figure 3. FRE-865 and FRE-867 RT Enclosures Connect the HDSL cable stub as listed in Table 3. The FRE-865 contains only one system (designated as System 1), the FRE-867 has two systems, System 1 and System 2. March 28, 2000 FRE-860, FRE-865, FRE-867, and FRE-868...
Page 11
Subscriber Subscriber Subscriber Sub- Sub- Sub- Cable Stub Cable Stub Cable Stub scriber Circuit scriber Circuit scriber Circuit Line Line Line Ring Ring Ring Install 5-pin protector plugs for all connected pairs. FRE-860, FRE-865, FRE-867, and FRE-868 March 28, 2000...
Connect a female Amphenol-ended subscriber cable to the subscriber line connector (not supplied) (see Figure Terminate the connector as shown in Table FRE-868 List 3 and List 4 provide for HDSL protection. Install 5-pin protector plugs on all connected pairs. March 28, 2000 FRE-860, FRE-865, FRE-867, and FRE-868...
Page 13
Connector Subscriber Connector Subscriber Sub- Sub- Sub- Cable Stub Cable Stub Cable Stub scriber Circuit scriber Circuit scriber Circuit Lines Lines Lines Tip Ring Tip Ring Tip Ring Ring Tip Ring Ring FRE-860, FRE-865, FRE-867, and FRE-868 March 28, 2000...
Use 6 AWG wire to ensure a good ground connection to the FRE-86x. For the FRE-860, FRE-865, and FRE-867, List 1 and List 1A, route the chassis ground wire through the small hole in the strain relief on the bottom of the RT Enclosure.
Close the RT Enclosure housing cover and use the 216 tool to secure the door. The installation is complete. ROUBLESHOOTING Refer to the COLU Technical Practice or RTLU Technical Practice for complete COT and RT troubleshooting procedures. FRE-860, FRE-865, FRE-867, and FRE-868 March 28, 2000...
Central Office Central Office Line Unit COLU Central Office Terminal Channel Unit Federal Communications Commission Ground High bit-rate Digital Subscriber Line HDSL Line Unit Power Remote Terminal Remote Terminal Line Unit RTLU March 28, 2000 FRE-860, FRE-865, FRE-867, and FRE-868...
PairGain during the 30-day warranty period is, at PairGain’s option, either (a) return of the price paid or (b) repair or replace of the software. [PairGain also warrants that, for a period of thirty (30) days from the date of purchase, the media on which software is stored will be free from material defects under normal use.
PairGain’s Return Material Authorization (RMA) Department. Call or write PairGain’s RMA Department to ask for an RMA number and any additional instructions. Use the telephone number, fax number or email address listed below: Telephone: 800.370.9670...
363-860-100-02, Revision 02 Product Support All shipments are to be returned prepaid. PairGain will not accept any collect shipments. FCC C OMPLIANCE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Page 20
Corporate Office 14402 Franklin Avenue Tustin, CA 92780 Tel: 714.832.9922 Fax: 714.832.9924 For Technical Assistance: 800.638.0031 714.730.3222...