PRL-771 Overview
Attach the HDSL Tip and Ring Wires
To attach the Tip and Ring wires:
Always treat the HDSL pair as if it were live with high voltage present. Review the safety precautions at
the beginning of this section before proceeding.
1
Use a #1 Phillipshead screwdriver to punch a second small hole in the bottom of the rubber grommet on the
left-hand bottom side of the RT enclosure (see Figure 8).
Cutting the grommet with a utility knife or something similar is not recommended, because this may
cause a large opening in the grommet, allowing insects or other contaminants to enter the enclosure.
2
Insert the service cable containing the HDSL Tip and Ring wires into the hole made in step 1.
3
Loosen only the top nut on the Tip and Ring gas tube protection binding posts (see Figure 8).
If this unit is to be pole mounted, ADC recommends that the subscriber drop wires be connected directly
to the appropriate gas tube protection binding posts.
10
Figure 8. Attaching the HDSL Tip and Ring Wires
January 6, 2003