Attach the Frame-Ground Wire

To attach the ground wire:
1
Use a 5/32-inch tamper-proof hex key to loosen the tamper-proof screw on the Telco Access door, then open
the Telco Access door (Figure 6)
2
Use a #1 Phillipshead screwdriver to punch a small hole in the bottom of the rubber grommet on the
left-hand bottom side of the RT enclosure (see Figure 7).
Cutting the grommet with a utility knife or something similar is not recommended, because this may
cause a large opening in the grommet, allowing insects or other contaminants to enter the enclosure.
3
Insert the frame-ground wire into the RT enclosure through the hole made in step 1. A 10 AWG copper
frame ground wire is recommended.
4
Loosen and remove from the ground-binding post the top nut and three flat washers.