Required Tools And Test Equipment; Installing The Rlu; Safety Precautions - ADC PG-PLUS Technical Practice

Remote line unit
Hide thumbs Also See for PG-PLUS:
Table of Contents

Advertisement

SCP-PRL771-012-05H
I
NSTALLATION AND
R
T
EQUIRED
OOLS AND
The tools and test equipment required for the RLU are:
One Telephone test set
One 1/4-inch flat-head screwdriver
One #1 Phillips screwdriver
One insulated-handle 3/8-inch nut driver
One 5/32-inch hex key, drilled for tamper-proof fasteners
One insulated-handle wire stripper
One insulated-handle needlenose pliers
One insulated-handle wire cutter
I
RLU
NSTALLING THE

Safety Precautions

To ensure the safety of personnel and equipment, carefully observe the following safety rules.
Be careful when installing or modifying telephone lines. Dangerous voltages can be present. It is unsafe to
install telephone wiring during a lightning storm.
Always disconnect all telephone lines and power connections before servicing or disassembling this
equipment.
For performance and safety reasons, use only power supplies listed with telephone equipment by a locally
recognized organization.
All wiring external to the product should follow the local wiring codes.
Always treat the HDSL pair as if it were live with high voltage present. Use caution when installing an HDSL
pair that is already connected to a COLU, because dangerous voltages are present on the HDSL pair. The
COLU, unless previously disabled by means of craft provisioning, periodically attempts to power up the
RLU by applying + 100 V dc with respect to ground to the HDSL pair. The COLU also initiates a start-up
after a momentary short has been applied to the HDSL pair. The COLU responds with start-up voltage
three seconds after removal of the short.
PG-Plus PRL-771
T
EST
T
E
EST
QUIPMENT
January 6, 2003
PRL-771 Overview
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

S9msbb0a

Table of Contents