Property
Units
Viscosity
cSt
40°C
Antioxidant
%
Acid No.
mg KOH/gm
TAN
Phosphorus
PPM
Zinc
PPM
Calcium
PPM
Barium
PPM
Iron
PPM
Copper
PPM
Lead
PPM
Tin
PPM
Aluminum
PPM
Silicon
PPM
Molybdenum
PPM
Water
PPM
Particle Count Microns
ISO CODE

FLUID PARAMETERS

QuinSyn, QuinSyn IV & QuinSyn F
Test Method
New Fluid
ASTM D-445
42-48
Liquid Chromatography
ASTM D-947
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Plasma Emission
Karl Fisher
Hiac Royco
16/14
Quincy Compressor – QSF Series
Section V– Servicing
Marginal
38-42, 48-52
0.1
0.8
0
0-20
0
0-20
0
0-20
0
0-20
0
5-10
0
5-10
0
5-10
0
5-10
0
5-10
0
10-15
0
0-20
<100
75-175
XX/19
Unacceptable
<38, >52
>0.9
>20
>20
>20
>20
>10
>10
>10
>10
>10
>15
>20
>200
XX/19
27