TL50 Pro Tower Light
Datasheet
50 mm Programmable Multicolor RGB Tower Light
Standard Compact Beacon
Standard
Omni-Directional
Sealed
Audible
Audible
Sealed Audible
Models
Family
Style
Housing
TL50
P
C
P = Pro
Blank = Standard
C = Compact
BL = Beacon
* Not available with audible
TL50 Pro models without audible have a 5-pin M12 quick disconnect for one through four segments and have an 8-pin M12 quick
disconnect for five to seven segments. Models with an audible segment have a 5-pin M12 quick disconnect for one through three
segments and have an 8-pin M12 quick disconnect for four through six segments.
Configuration Instructions
Pro Editor
Original Document
209142 Rev. D
Rugged, cost-effective, and easy-to-install multi-segment tower lights
Programmable using Banner's Pro Editor software and Pro Converter Cable
Illuminated segments provide easy-to-see operator guidance and indication of
equipment status
Up to 7 segments available
Available in black or light gray housing to match different machine styles
Audible models available with standard, sealed, or omni-directional audible element
Compact and beacon models are more intense in a smaller form factor compared to
standard models
10 V DC to 30 V DC operation
Bimodal inputs (PNP/NPN), depending on source wiring
Number of
Segments
Audible
3
1 = 1 Segment
Blank = None (IEC IP67)
2 = 2 Segments
A = Audible (IEC IP50)
3 = 3 Segments
ALS = Sealed Audible Continuous Tone
4 = 4 Segments
AOS = Omni-Directional Sealed Audible
5 = 5 Segments
Continuous Tone
6 = 6 Segments
AOSI = Omni-Directional Sealed Audible
7 = 7 Segments *
Continuous Tone with Intensity Adjust
Use Banner's Pro Editor software and Pro Converter Cable to create custom
configurations by selecting different colors, flash patterns, and animations.
For more information visit www.bannerengineering.com/proeditor.
19 October 2021
Housing
Color
A
Blank = Black
C = Cool Gray
Blank = 2 m integral cable
Q = 5-pin or 8-pin M12 QD
QP = 150 mm cable with a 5-pin
or 8-pin M12 QD
Connector
Q
209142

Advertisement

loading

Summary of Contents for Banner TL50 Pro Series

  • Page 1 8-pin M12 quick disconnect for four through six segments. Configuration Instructions Pro Editor Use Banner's Pro Editor software and Pro Converter Cable to create custom configurations by selecting different colors, flash patterns, and animations. For more information visit www.bannerengineering.com/proeditor.
  • Page 2 A = Pro Converter Cable (MQDC-506-USB) B = Splitter (CSB-M1251FM1251M) C = PC running Pro Editor software D = Any Banner Pro Series-enabled device (K50 shown) E = Power Supply (PSW-24-1 or PSD-24-4) F = 8-Pin to 5-Pin Double-Ended Cordset (MQDC-801-5M-PRO),...
  • Page 3 Pro Editor Configuration for the TL50 Pro Banner's Pro Editor software offers an easy way to configure Pro Series-enabled touch and indicator devices, allowing users full control of device states. The easy-to-use configuration software provides a variety of tools and capabilities to solve a wide range of applications.
  • Page 4 TL50 Pro Tower Light Run or Action Mode Description Animation 50/50 Color 1 is displayed on 50% of every segment and Color 2 is displayed on the other 50% of every segment at the defined color intensities and segment shift 50/50 Rotate Color 1 is displayed on 50% of every segment and Color 2 is displayed on the other 50% of every segment while rotating at the defined speed, color intensities, rotational direction, and segment shift...
  • Page 5: Specifications

    TL50 Pro Tower Light Global Parameters and Description Advanced Settings Determines the signal value change needed to transition between thresholds and to prevent chatter Hysteresis None: The value follows the input signal High: A large value change is needed to transition between thresholds Specifications Supply Voltage and Current Audible Adjustment...
  • Page 6 TL50 Pro Tower Light Indicator Characteristics Color Coordinates 1 Lumen Output Per Segment (Typical at 25 °C) Dominant Wavelength (nm) or Color Color Temperature (CCT) Standard Compact Beacon 0.689 0.309 Green 0.154 0.700 17.5 14.1 21.8 Yellow 0.477 0.493 23.8 18.9 29.2 Blue...
  • Page 7 TL50 Pro Tower Light Table 2: Compact and Beacon Models Figure 2. Compact and Beacon Model Dimensions Omni- Standard Non-Audible Sealed Audible Directional Audible # of Segments Sealed Audible 46.2 (1.9) 77.1 (3.1) 110.2 (4) 114.2 (4.5) 72 (2.9) 102.9 (4.1) 126 (5) 140 (5.5) 97.8 (123.6)
  • Page 8 TL50 Pro Tower Light Cordsets 5-Pin Threaded M12 Cordsets—Single Ended Model Length Style Dimensions Pinout (Female) MQDC1-501.5 0.5 m (1.5 ft) 44 Typ. MQDC1-506 2 m (6.5 ft) Straight MQDC1-515 5 m (16.4 ft) M12 x 1 MQDC1-530 9 m (29.5 ft) ø...
  • Page 9 TL50 Pro Tower Light Splitter Cables for Use with IO-Blocks 5-Pin Threaded M12 to 4-Pin Threaded M12 Combiner Cordset with Flat Junction Model Branches (Male) Trunk (Female) Pinout 4-pin Quick Disconnect, 2 × 0.31 m (1.02 Female CSF-M12F51M12M41 5-pin Quick Disconnect, 0.31 m (1.02 ft) Male ø4.5 49.0 Typ.
  • Page 10: Mounting Brackets

    TL50 Pro Tower Light Mounting Brackets All measurements are listed in millimeters [inches], unless noted otherwise. SMB30A SMB30FA 83.2 • Right-angle bracket with curved • Swivel bracket with tilt and pan slot for versatile orientation movement for precise adjustment • Clearance for M6 (¼...
  • Page 11 TL50 Pro Tower Light Elevated Mount System Model Features Components SA-M30TE12 - Black Acetal • Streamlined black acetal or white UHMW stand-off pipe adapter/cover • Connects between 30 mm light base and ½ in. NPSM/ SA-M30TE12C - White UHMW DN15 pipe •...
  • Page 12: Fcc Part 15 And Can Ices-3 (B)/Nmb-3(B)

    Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

This manual is also suitable for: