The table below lists typical current consumption for analogue dimming line and is valid for a single
module.
Signal
Analogue dimming
Analogue dimming
Analogue dimming
Analogue dimming
Analogue dimming
Table 12: Analogue dimming signal power requirements for a single unit.
When multiple illuminators are connected in daisy-chain operation, please consider the typical
current consumptions listed below.
Signal
Analogue dimming
Table 13: Analogue dimming signal power requirements for multiple

10.6 Led indicator

LTBRZ3-C series is equipped with a RGB led indicator used to monitor both status and error
conditions. The table below describes the led behavior.
Led status and color
Solid green
Solid blue
Alternately flashing
V 1.00 - eng
Voltage
10 V
24 V
Voltage
2 units
24 V
4 mA
Power supply is present, illuminator is OFF.
Power supply is present, illuminator is ON.
Error condition is detected.
Table 14: LED indicator signalling behavior.
0 V
1 V
5 V
Current consumption
3 units
6 mA
RGB Led indicator
Illuminator status
Current consumption
~ 0.000 mA
0.025 mA
0.125 mA
0.250 mA
< 2 mA
4 units
8 mA
units.