Enable Signals - opto engineering LTBRZ3-C Series Instruction Manual

Led bar lights with integrated driving electronics
Table of Contents

Advertisement

LTBRZ3-C series | INSTRUCTIONS MANUAL

10.4 Enable signals

LTBRZ3-C Series can be turned ON or OFF by applying proper signals to the input pins named PNP
enable and NPN enable.
Signal
PNP enable
NPN enable
Leave signals unconnected if not used
Do not try to force both PNP and NPN simultaneously.
The table below lists typical current consumption for both lines (PNP, NPN) and is valid for a single
module.
Driving the enable with a 3.3 V signal is not recommended.
Signal
PNP enable
PNP enable
PNP enable
NPN enable
When multiple illuminators are connected in daisy-chain configuration, please consider the current
consumptions listed below.
Signal
PNP enable
PNP enable
PNP enable
NPN enable
V 1.00 - eng
Apply >4V to turn on the light
Apply <1 to turn on the light (connect to GND)
Table 7: PNP and NPN signals operating range.
Voltage
5 V
12 V
24 V
0 V
Table 8: PNP and NPN signals power requirements for a single unit.
Voltage
5 V
12 V
24 V
0 V
Table 9: PNP and NPN signals power requirements for multiple units.
Value
PNP/NPN current consumption
2 units
6 mA
15 mA
30 mA
24 mA
Safety range
0V to 24V
0V to 24V
Current consumption
3 mA
7.5 mA
15 mA
12 mA
3 units
9 mA
22.5 mA
45 mA
36 mA
4 units
12 mA
30 mA
60 mA
48 mA