Leakomatic Pro1 User Manual page 14

Hide thumbs Also See for Pro1:
Table of Contents

Advertisement

Available languages

Available languages

Flow test (FT)
FT alarms
FT time Away
FT time Home
FT alarm delay
Quick test (QT)
QT alarms
QT index limit
QT alarm delay
Tightness test (TT)
TT alarm
TT number
TT duration
TT alarm delay
14
Indicates whether the device is monitoring types
of flow or not. If "Disabled" is selected, the
below mentioned FT alarm times do not have an
effect.
The Away mode allows the magnetic valve to
close. It activates the alarm after the water has
flowed longer than the set time of flow.
Indicates the time that the flow of water is
allowed in Home mode before the flow alarm
sounds. In the Home mode, the magnetic valve
closes if the flow continues for that much longer
that the selected delay time is exceeded.
Indicates the additional time that the flow of
water is allowed in Home mode before the valve
closes.
Indicates whether Quick test has been activated
or not. If "Disabled" is selected, the below
mentioned QT alarm times do not have an effect.
Indicates the index limit that causes Quick test
to sound an alarm.
When the quick test alarm sounds, you can set
an additional time that indicates how long the
drip is allowed to continue before the valve
closes.
Indicates whether Tightness test has been
activated or not. If "Disabled" is selected, the
below mentioned TT alarm times do not have an
effect.
Indicates the number of periods per day when
the tightness test must be approved. If the
number is high, the system should be more
closely monitored.
Indicates the required duration of the pulseless
period per day in order to approve a tightness
test. If the number is high, the system should be
more closely monitored.
When the tightness test alarm sounds, you can
set an additional time that indicates how long the
alarm is allowed to sound before the valve closes.
Enabled/
Disabled
1–999 s
(20)
1–240 min
(20)
0–240 min
(5)
Enabled/
Disabled
0.10–5.00
(1.00)
0–24 hours
(1)
Enabled/
Disabled
1–12
(1)
1–60 min
(15)
0–7 days
(1)

Advertisement

Table of Contents
loading

Related Products for Leakomatic Pro1

Table of Contents