Saftey Information
1. The temperature is CELSIUS!
2. Be sure to operate with safe ground wire!
3. Check the voltage before using it. The providing voltage must be the same as the
machine's. (Normally 2480F~3920F / 1200C~2000C).
4. When you change parts, please turn o the machine and switch o the power supply!
5. Please put on heat insulation gloves when you touch the heating part.
6. When you use it, avoid heating the machine without operating it for long time, You
should switch o the power supply when you don't use it. You can also put one work piece
which is useless on it to avoid heating nothing.
7. Avoid touch the press spring when you operating in case be injured.
8. When you press the handle, if you fell the press is too much and it is hard to press it,
please adjust the press adjusting knob, decrease the shrink of the spring or the intensity of
the machine will be injured.
9. When you get the main body lift of descend, please loose the xation screw. If you fell
palpable resistance when you use the press adjusting knob, please don't go on doing it!
10. Don't over close it when xing the main body. It is OK when you feel resistance.
11. Keep children a way from the machine even when the machine is left unused!
NOTE:
1) Please switch off the machine and unplug the power cord when the machine is not in use.
2) The heat platen will cool down to room temperature if heat press stays unused for more than 30 minutes.
3) For better maintenance of the heat press, the maximum temperature used should be 410 degrees F.
4) When printing double sided T-Shirts, insert a teflon sheet in between the shirt to protect the ink.
5) Heat platen may pivot slightly back and forth. This is due to movement allowance within the
assembled clamp, and is normal.

Troubleshooting

1. Machine will not power on.
A). Check the plug to make sure it is connected to a grounded wall socket.
B). Check the power switch or digital controller.
C). Check the fuse to make sure it is not burnt out.
D). Indicating light is on, but no display on screen, check the 5 cable of Railway transformer. If it is loose, the
problem may be a poor connection.
2. The display screen is working well, but the temperature does not increase on the heat platen.
A). Check if the indicating light of solid-state relay is on.
B). If you already changed the new solid-state relay but the heat platen will not heat up, check if the heat platen
power cable is loose.
3. The heat platen works well, but suddenly the display screen show 437ºF.
A). Check whether the thermocouple of the heat platen is connected firmly.
4. The machine is heating up, but the temperature jumps to above 437ºF or 572ºF
or the temperature jumps irregularly.
A). Check whether the thermocouple of the heat platen is connected firmly.
5. The temperature is out of control: Set 356ºF,but the actual temperature is above 392ºF.
A). Relay may need to be changed.
B). Or the digital controller may need to be changed.
If you need further assistance, please kindly contact Pro World for support: 800-678-8289