8600 Installation Manual
J3 - Connector Description (continued)
PIN
Signal
J3.8
IN1
J3.9
GND
J3.10
OUT2
J3.11
OUT3
J3.12
OUT4
J4 - Connector Description: Sensor power and electric lock outputs
PIN
Definition
J4.1
(Output) + 24 VDC (500mA Max)
J4.2
(Output) +12 VDC (1,000mA Max)
J4.3
(GND) Ground reference for signals and power.
J4.4
(Output) Electric lock relay N.C. (Normally Closed)
J4.5
(Output) Electric lock relay N.O. (Normally Open)
J4.6
(COM) Electric lock relay common
J5 - Connector Description: Motor output (isolated from power input)
PIN
Definition
J5.1
Motor Positive
J5.2
Motor Negative
J5.3
AC Ground
J6 - Connector Description: Motor encoder
PIN
Definition
J6.1
(Output) +5 VDC
J6.2
(Input) Encoder Signal B
J6.3
(Input) Encoder Signal A
J6.4
COM (Ground)
J7 - Connector Description: ISP/SNYC/Communication
PIN
Definition
J7.1
(Output) PDO
J7.2
(Output) +5 VDC
J7.3
(Output) SCK
J7.4
(Input) PDI
J7.5
(Input/Output) RST
J7.6
COM (Ground)
J8 - Connector Description: Battery Back-up Charger
PIN
Definition
J8.1
Ground
J8.2
(Output) 24 VDC
Definition
(Input) Not used.
Ground reference for signals and power.
(Output) Not used.
(Output) Not used.
(Output) Not used.
35