8600 Installation Manual
8.19 Special Function Normal
This setting is used for Access Control options, including Electric Strikes/Locking devices.
This requires a Wet Input connection to Open. A Wet Input will activate the Strike/Lock and open the door
simultaneously.
Use the "UP" and "DOWN" buttons to select from Normal, Access or Access→Activate.
Normal = default settings.
Access = only the Strike/Lock will release and the exterior "ACT2" button turns on, so the pedestrian
will need to perform a "Knowing Act" for the door to Open.
Access→Activate = door and Strike/Lock activate simultaneously when a validated credential is
presented.
8.20 In1 Wet Input
This feature is used with the "Special Function" feature above for external Access Control options that are
either Normally Open or Normally Closed (NO/NC) using the Wet-IN1 input terminal on the board.
Typical Access Control devices are: Key Pads, Card Readers, Proximity Cards, etc.
Use the "UP" and "DOWN" buttons to select the NO/NC circuit required by the Access Control device.
Normally Open = Access Control device will send 12/24vdc power to the control unit.
Normally Closed = Access Control device takes the 12/24vdc power away from the control unit.
8.21 This Door Overlaps
This is used for a Double door operator application when there is a door overlap.
This setting will Enable or Disable the Double swing door Co-ordinate feature.
Use the "UP" and "DOWN" buttons to Enable or Disable this feature.
8.22 Factory Reset
This setting will Restore the control unit to its original Factory settings, all current settings will be lost.
To reset the control to the original settings, push the "UP" button, then push "ENTER" button to confirm.
You will need to reprogram all features and settings of the control unit.
8.23 Display Light On
This feature sets the length of time in minutes the LED display will remain on after the last button has been
pushed on the control unit.
8.24 Operator Type
This setting is used to select which type of Operator functionality you want for this application.
WARNING: The "Full Automatic" mode can NOT be selected unless all requirements of this installation
complies with the ANSI/BHMA A156.10 Standard for Power Operated Pedestrian Doors including, but not
limited to, Safety Sensors and Guardrails.
Use the "UP" and "DOWN" buttons to select.
8.25 Safety 2 Inhibit
Safety 2 will be deactivated at the point where the Safety sensor would pick up a wall or fixed object adjacent
to the door.
This setting will inhibit the Safety Sensor (back side of the door) in order to allow the door to fully open.
(Access/Access→Activate).
(Normally Opened/Normally Closed)
(Yes/No)
(Yes/No)
Time (01-30 minutes)
(Low Energy/Full Automatic)
at (30%-98%)