J6
J5
J1
J1 - Connector Description: Power input 100-240VAC (100W max.)
PIN
Definition
J1.1
AC Ground
J1.2
AC Neutral
J1.3
AC Line (Fused)
J2 - Connector Description: Hold open/OFF/Auto switch input
PIN
Definition
J2.1
Auto signal - This signal (to GND) will allow activation
J2.2
GND - Ground reference for signal and power
J2.3
Hold Open - This signal (to GND) will activate the operator to hold the door open.
J3 - Connector Description: Accessories and Sensors Inputs and Outputs
PIN
Signal
J3.1
GND
J3.2
ACTIVATION 1
J3.3
ACTIVATION 2
J3.4
SAFETY 1
J3.5
SAFETY 2
J3.6
PC CANCEL
OUT1
J3.7
DOOR CLOSED
J7
Definition
Ground reference for signal and power.
(Input) This signal (to COM) will activate the operator. If "AUTO" signal (J2.3) is to
COM and no current fault is present.
(Input) This signal (to COM) will activate the operator. (If "AUTO" signal (J2.3) is to
COM with no current fault present and door is not fully closed.
(Input) When the door is fully closed, this signal (to COM) will prevent an
activation. When the door is fully opened, this signal (to COM) will prevent the
door from entering the closing cycle.
(Input) When the door is fully closed, this signal (to COM) will prevent and
activation. When safety signal clears, pending activation will activate the operator.
During the opening cycle, the door will go to safety (Hold) speed. (When the signal
is to COM). When the door is fully opened, this signal (to COM) will prevent the
door from entering the closing cycle.
(Input) This signal (to COM) will prevent or cancel power close.
(Output) This signal is tied to COM when door is fully closed. Door must be set up
(Learning Completed).
J8
J4
J3
J2