4.4. All servo on and auto adjustment.
When Cursor u button is pressed, all servos turn on, auto adjustment is performed and switch to playback operation.
(Playback sound output)
Stop (stop to the playback state after auto adjustment)
When SOURCE button is pressed, play operation and servo stop. The following will be displayed.
After stopping, conduct reading of auto adjust values.
Stop (stop to the playback state after auto adjustment)
When Cursor u / i button is pressed, the adjustment values are displayed in the following order.
q FOCUS BALANCE
w FOCUS GAIN
e TRACKING BALANCE
r TRACKING GAIN
t FOCUS OFFSET
y TRACKING OFFSET
u RFRP
(Caution) If you have not completed the adjustment, the value is not correct.
4.5. All servo on and auto adjustment.
When VOLUME d button is pressed for over 1 second while the RCD-N7 is in the CD TEST MODE, the laser turns on
and the laser current is measured.
The laser drive current undergoes A/D conversion for calculation.
The current value is updated every 3 seconds.
Press the SOURCE button, CD TEST MODE display reappears.
Stored data is not cleared, even when the RCD-N7 is reset(Factory/User).
Overwriting the stored data
When the 1 / 3 ENTER button is pressed for over 5 seconds while the laser current is displayed, thecurrent value is
stored in the EEPROM (overwriting the stored data).
Once rewriting is completed, the display in "Laser current display" reappears.
Rewriting is performed upon shipment from the factory and when the mechanism is replaced.