System Configuration; Equipment Controller Configuration - Carrier ZONECC2KIT-B Installation And Start-Up Instructions Manual

Table of Contents

Advertisement

DEFROST
JUMPER NEEDED
FOR HEAT PUMP
APPLICATIONS
SEE
FIGURES FOR
EQUIPMENT
WIRING
24 VAC ZONING
TRANSFORMER
ZONE 1
DAMPER
ZONE 2
DAMPER
ZONE 3
DAMPER
ZONE 4
DAMPER
ZONE 5
DAMPER
ZONE 6
DAMPER
ZONE 7
DAMPER
ZONE 8
DAMPER
8
1
NOTES:
heat. This acts to prevent the unnecessary use of auxiliary heat. In
addition, when an outdoor sensor is attached, the system can be set
to lock out auxiliary heat for outdoor temperatures above an
installer selectable value. This will be covered under System
Configuration.

SYSTEM CONFIGURATION

Comfort Zone II -B must be configured to match the type of
equipment connected to it. In addition, there are several choices of
configuration based on how the user wants the system to operate.
Configuration is done in 2 parts. First is the setting of 8 DIP
switches on the Equipment Controller. The second is a group of
software selections made via User Interface. Follow the sequence
below for easy setup.
Configuration of the Equipment Controller is done first with the
power off. Then power is applied and the User Interface is
configured with power on.
NOTE: A DIP switch module is oriented with switch 1 at the
bottom and switch 8 at the top. Refer to Fig. 12 for switch
orientation and labels.
Step 1—Equipment Controller Configuration
Located near bottom of Equipment Controller circuit board, there
is an 8 section DIP switch. The use of each switch is described
8 ZONE EQUIPMENT CONTROLLER
DEF DEFROST
DAMPER
DHUM DEHUMIDIFY
HUM HUMIDIFY
O REVERSING VALVE COOL
B REVERSING VALVE HEAT
RH HEATING TRANSFORMER
RC COOLING TRANSFORMER
G FAN
W2 HEAT STAGE 2
W1 HEAT STAGE 1
Y2 COMPRESSOR STAGE 2
Y1 COMPRESSOR STAGE 1
C
RZ
CLS1
COM1
OPN1
CLS2
COM2
OPN2
CLS3
COM3
OPN3
CLS4
DAMPERS
COM4
CLS_
=
CLOSE
OPN4
COM_
=
COMMON = 24VAC FROM RZ
CLS5
OPN_
=
OPEN
COM5
OPN5
CLS6
COM6
OPN6
CLS7
COM7
OPN7
CLS8
COM8
OPN8
OPTION
SWITCHES
NOTE SWITCH
#8 IS AT TOP
*
= OPTIONAL COMPONENTS
= INSTALLING ZONE 1 REMOTE SENSOR AT OS1 AND OS1C WILL OVERRIDE
TEMPERATURE SENSOR ON USER INTERFACE
= COMMUNICATION BUS ARE IN PARALLEL WITH EACH OTHER
(EITHER CONNECTOR CAN BE USED)
Fig. 11—8-Zone System Wiring Diagram
FUSE
3A
D20
(LED)
COMMUNICATION
BUS
COMMUNICATION
BUS
REMOTE
SENSORS
below. Using a pen or pencil, set each switch to its proper state.
ON is to the left and is the factory setting. OFF is to the right. Fig.
12 is a pictorial drawing of this selector switch.
Switch 1—Selects AC or HP.
ON—Selects AC.
OFF—Selects HP.
Switch 2—Selects single- or 2-speed compressor.
ON—Selects single speed.
OFF—Selects 2 speed.
Switch 3—Selects 3-stage electric heat. Equipment must include
FK or FV series fan coil with single-speed heat pump and properly
selected 3-stage electric heater.
ON—Normal 1- or 2-stage electric heat.
OFF—Special 3-stage electric heat.
Switch 4—Selects Smart Recovery in both heating and cooling.
The system starts adjusting temperature 1-1/2-hours earlier than
selected recovery time so it will arrive at new temperature at
selected time.
ON—Smart recovery.
OFF—Normal recovery.
Switch 5—Zone system address selection. When 2 zoning systems
are connected together, the second system should be set to OFF.
8
P
NA
WIRELESS
D
RECEIVER*
C
NA
G
OAT
OUTDOOR AIR
TEMP SENSOR
OATC
LAT
LEAVING AIR
TEMP SENSOR
LATC
HPT
HEAT PUMP
TEMP SENSOR
HPTC
USER INTERFACE
V+
RS+
BLUE/YELLOW
GREEN
RS-
WHITE
VG
SMART SENSORS*
V+
RS+
BLUE/YELLOW
GREEN
RS-
WHITE
VG
OPTIONAL
OS1
ZONE 1
OS1C
SENSOR
ZS2
ZONE 2
ZS2C
SENSOR
ZS3
ZONE 3
SENSOR
ZS3C
ZONE 4
ZS4
SENSOR
ZS4C
ZS5
ZONE 5
SENSOR
ZS5C
ZONE 6
ZS6
SENSOR
ZS6C
ZS7
ZONE 7
SENSOR
ZS7C
ZS8
ZONE 8
SENSOR
ZS8C
RED
V+
RS+
RS-
VG
RED
V+
RS+
RS-
VG
A98084