Dip Switch Setting - Furuno CI-35 Installation Manual

Doppler sonar current indicator
Hide thumbs Also See for CI-35:
Table of Contents

Advertisement

DIP switch settings on each board
Symbol
PCB
No.
S1
JIFA
66P3800
S2
Factory Setting
NO.
ON
OFF
NMEA
OFF: Ver. 2.0 (With check sum at last output data)
1
ON: Ver. 1.5 (Without check sum)
2
No use
Log pulse out
OFF: Forward only
3
ON: Forward and Backward
No use
4
5
CH-35:
No use
6
Depth data format
7
OFF: CIF, ON: NMEA
Temperature data format
8
OFF: CIF, ON: NMEA
Bearing data format
1
2
ACD: AD converter (Furuno clocked-serial)
Log pulse measurement layer
3
OFF: Reference layer, ON: 1
4
Set to ON when S #3 is off.
Bearing output at slow speed (less than 0.5 kts)
5
OFF: True bearing, ON: Heading
Bearing output data
6
OFF: True bearing, ON: Heading
Signal level of AUX port
7
OFF: Current loop, ON: RS-232C
CIF data ON/OFF
8
OFF: Standard, ON: Option
4-10
CH-35H:
Receive data format for AUX port (Effective when
S2-1/2 are set to ON.)
5
OFF
6
OFF
Data
under
fined
DAT1: TKC (<CR>DDDdd)
DAT2: TKC (DDDd*<LF>)
DAT3: Hokushin ($HERHRC, DDDdd, +/-RRr*cs)
1
OFF
2
OFF
Sensor
ADC
Functions
ON
OFF
ON
OFF
ON
ON
DAT3
DAT2
DAT1
ON
OFF
OFF
ON
CIF
NMEA
st
layer
ON
ON
AUX

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ci-35h

Table of Contents