3.7 Matching Box
The transducer cable is relayed at the matching box to connect with the transceiver
unit.
1) Transducer cable (coaxial cable).
2) 4 pair cable 66S1067 (with armor)
Attach crimp-on lugs. Fabricate the armor as bellows.
Anticorrosive
Sheath
Solder
vinyl wire.
Vinyl sheath
Fig.3-24 Fabrication of coaxial cable
Clamp vinyl sheath
Armor
by cable gland.
Rubber gasket
Gland
To earth terminal
(wing nut)
Fig. 3-25 Fabrication of 66S1067
35 mm
15 mm
2 mm
Solder the core.
3-15