Junction Box - Furuno CI-35 Installation Manual

Doppler sonar current indicator
Hide thumbs Also See for CI-35:
Table of Contents

Advertisement

3.4 Junction Box

The transducer cable is connected to the junction box with an extension cable. After
making the connection, seal the cable gland with putty for watertightness.
1) Transducer cable 66S1066 (without armor)
Vinyl Sheath
Rubber Packing
Grand
2) 4 pair cable 66S1067 (extension cable, with armor)
Attach crimp-on lugs in the same manner as shown above. Fabricate the armor as
follows.
Anticorrosive
Sheath
Solder
vinyl wire.
Cut to suitable length considering location on terminal board.
FV5.5 (YEL)
Vinyl Tape
Vinyl Tape
Fig. 3-7
Clamp vinyl sheath
Armor
by cable gland.
Rubber gasket
Gland
To earth terminal
(wing nut)
Fig. 3-8
3-5
FV1.25-4
Vinyl Tubing
To internal earth stud
FV2-P4
See Interconnection
Diagram

Advertisement