INSTALLATION
CLEARANCES
MAXIMUM ALLOWABLE DUCT LENGTHS BLAZE 600 D – Total 150ft (Max 24ft on inlet)
RETURN DUCTS 16" or optional 2 X 12"
SUPPLY DUCTS 2 X 12" or optional 16"
THIS HEATER IS FOR USE WITH AND WITHOUT DUCTWORK
WHEN USING DUCTWORK AVOID ANY KINKS OR SHARP BENDS.
INSUFFICIENT INLET AIR OR INSUFFICIENT DISCHARGE AIR WILL CAUSE
THE HEATER TO OVERHEAT.
BLAZE 600 D TURBO MAINTENANCE INSTRUCTIONS
WARNING
EVERY CONSTRUCTION HEATER SHOULD BE INSPECTED
BEFORE EACH USE, AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE
PERSON. INCORRECT MAINTENANCE MAY RESULT IN IMPROPER
OPERATION OF THE HEATER AND SERIOUS INJURY COULD OCCUR.
HOSE ASSEMBLIES
The hose assemblies shall be visually inspected prior to each use of the heater. If it is evident there is excessive
abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement
hose assembly shall be that specified by the manufacturer.
TEMPERATURE CONTROLLER AND THERMOCOUPLE
The temperature controller protocols should be checked every heating season to ensure the burner will shutdown if
temperature exceeds 280F at the outlet duct. This can be accomplished by restricting the air flow through the unit.
After tests are complete, remove restrictors as both inlet and outlet ducts must be open for proper operation.
The temperature controller setting of 90 °F has been selected to allow for preheating of the heat exchanger to ensure
that only heated air is allowed to enter the space. Upon satisfying the need for heat, the temperature controller will