Frequently Asked Questions; Technical Data - Chamberlain SLA230E Manual

Remote light
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7

Frequently asked questions

Light does not come on
Light comes on during
day
Light comes on for no
obvious reason
Light seems to be on
all the time
Range of remote con-
trol too small

Technical data

Input voltage – power supply unit
Cable length
Voltage – lighting
Standby consumption
Operation – consumption
Sensor range
Lighting
Lamp weight
Number of settable remote controls
Frequency
Operating temperature
Degree of protection
• It is too bright (during the day)>50lux
• Lamp is not switched on
• Movement sensor is not activated
• Remote control is not set
• Remote control too far away from lamp
• Sensor is mounted in a dark location
• Lamp is set to TEST
• Sensor detects small movements:
animals or cars
• Radio remote control is activated
• Non-compatible remote control has
been set
• Switch is in TEST position
• Sensor is activated via heat source
• Radio signal reaches location too late
• Other radio signals interfere with
installed receiver
• Non-compatible remote control is
being used
230 V 50 Hz
2.5 m
6 V
0.35 Watt
2.6 Watt
max. 15 m & 180° (depending on mounting height)
OFF / 1 or 5 minutes
0.25 kg
15
433.92 MHz
-20°C - +65°C
IP44
• Check again when it's dark
• Check mains socket and cable
• Move closer to sensor or change
setting
• Set remote control (use compatible
remote control)
• Move closer to lamp
• Change location
• Change setting
• Reduce range of sensor
• Avoid
• Clear all remote controls and only use
compatible Chamberlain remote con-
trols
• Change setting
• Avoid heat source or change range
setting of sensor
• Change location
• Change location or avoid interferences
through other radio controlled devices
• Clear all remote controls and only use
compatible Chamberlain remote con-
trols
4-en

Advertisement

Table of Contents
loading