GENERAL SAFETY INFORMATION (CONTINUED)
CAUTION
Do not install this ventilating fan in a location where the interior room temperature may exceed 104 °F (40 °C).
Make sure that the electric service supply voltage is AC 120 V 60 Hz.
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the
Occupational Safety and Health Administration (OSHA).
Always disconnect the power source before working on or near the fan, motor or junction box.
Protect the supply wiring from sharp edges, oil, grease, hot surfaces,
chemicals or other objects.
Do not kink the supply wiring.
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
Not for use in cooking area. (Fig. A)
The special-purpose or dedicated parts, such as
mounting fixtures, must be used if such parts are
provided.
Provide make up air for proper ventilation.
Do not connect multiple units in parallel. If two or more units are connected to one switch in parallel, the units
may not function.
Do not install the unit where ducts are configured as shown in below:
Excessive bending
DESCRIPTION
These products are listed by UL under UL file No. E78414.
These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to
have long operating life, high dynamic response, higher speed ranges and energy savings. The grille covering the fan
body is a spring-attached, quick removal type. A damper for preventing air counter flow is provided. The blower uses
a high-capacity sirocco fan developed to reduce the noise level.
(RG-C811HA only)
This Panasonic ventilating fan model is equipped with a humidity sensor that turns on automatically when humidity
increases rapidly, or when humidity rises above a 30% - 80% relative humidity set-point. It is user-adjustable to
operate 0.5 ~ 60minutes after the sensors are no longer detected.
Successive bending
Squeezed duct
Bend close to duct adaptor
(Cooking area)
Do not install above or
inside this area
Floor
Cooking
equipment
Fig. A
Adaptor
3