Table 2. Resistive Signatures
Test
Failure Condition
RT Equipment
RT detected, but no
Failure
response from RT
Foreign Voltage
TG or RG > 10 V
rms
on Drop
TG or RG > 6 Vdc
All Tests OK
No failures Detected
Ringer Test
REN > 5.0 or < 0.2
Resistive Fault
TG, RG, or TR > 150 K
on Drop
Receiver Off-
Phone is off-hook
hook
Hazardous
TG or RG > 50 V
rms
Potential on
TG or RG > 135 Vdc
Drop
COT-RT
RT not detected
Facility Failure
NOTE: The signatures for the AMU-912 L1 are biased to
-14 Vdc.
Network T1/HDSL Assignments
The T1/HDSL cable assignments are shown in Table 3. Note
that these circuits are terminated to the HyperEdge shelf
located below the PG-Flex
chassis. The DS-1 interfaces
Plus
between these shelves are hard-wired and are not field
accessable.
Table 3. Network T1/HDSL Cable Assignments
Protector
Socket
Tip
Ring
Description
White
Blue
Receive/Loop 1
1
HyperEdge 1/1
White
Orange Receive/Loop 1
2
HyperEdge 1/2
White
Green
Receive/Loop 1
3
HyperEdge 1/3
White
Brown
Receive/Loop 1
4
HyperEdge 1/4
White
Slate
Receive/Loop 1
5
HyperEdge 1/5
Red
Blue
Receive/Loop 1
6
HyperEdge 1/6
Table 3. Network T1/HDSL Cable Assignments
TR
TG,RG
Protector
Socket
(k
)
(k
)
7
17.8
90.9
8
27.8
90.9
38.3
90.9
9*
48.3
90.9
10*
58.0
90.9
11*
68.0
90.9
12*
78.5
90.0
13-25
26
>1,000
90.9
27
28
29
30
31
32
33
Conn
34*
35*
7
Tip
Ring
Description
Conn
Red
Orange Receive/Loop 1
HyperEdge 2./1
Red
Green
Receive/Loop 1
HyperEdge 2/2
Red
Brown
Receive/Loop 1
HyperEdge 2/3
Red
Slate
Receive/Loop 1
HyperEdge 2/4
Black
Blue
Receive/Loop 1
HyperEdge 2/5
Black
Orange Receive/Loop 1
HyperEdge 2/6
Not Used
White
Blue
Transmit/Loop 2
HyperEdge 1/1
White
Orange Transmit/Loop 2
HyperEdge 1/2
White
Green
Transmit/Loop 2
HyperEdge 1/3
White
Brown
Transmit/Loop 2
HyperEdge 1/4
White
Slate
Transmit/Loop 2
HyperEdge 1/5
Red
Blue
Transmit/Loop 2
HyperEdge 1/6
Red
Orange Transmit/Loop 2
HyperEdge 2./1
Red
Green
Transmit/Loop 2
HyperEdge 2/2
Red
Brown
Transmit/Loop 2
HyperEdge 2/3
Red
Slate
Transmit/Loop 2
HyperEdge 2/4
Page 2 of 11
Table 3. Network T1/HDSL Cable Assignments
Protector
Socket
Tip
Ring
Black
Blue
1
36*
Black
Orange Transmit/Loop 2
0
37*
38-50
A
* Wired for future use
HDSL and Auxiliary Power Assignments
HDSL and auxiliary power pairs are hard-wired between the
PG-Flex
shelf and the 'C' and 'D' 710 cables located in
Plus
the side splice chamber. Refer to Table 4 for FLL-814 cable
pair assignments and Table 5 for PLL-735 cable pair
assignments
Table 4. PG-Flex
Plus
Protector
Socket
Tip
Ring
White
Blue
51
7
White
Orange
52
1
White
Green
53
0
White
Brown
54
B
White
Slate
55
Red
Blue
56
Red
Orange
57
Red
Green
58
Red
Brown
59
Red
Slate
60
Black
Blue
61
Description
Conn
Transmit/Loop 2
HyperEdge 2/5
HyperEdge 2/6
Not Used
FLL-814 Cable Assignments
Description
Connector
Loop 1
Power 1
Loop 1
HDSL1
Loop 1
Power 2
Loop 1
HDSL2
Loop 1
Power 3
Loop 1
HDSL 3
Loop 1
7
Power 4
Loop 1
1
HDSL 4
Loop 1
0
Power 5
Loop 1
C
HDSL 5
Loop 1
Power 6