Feed appropriate supply cable (see 'a' in Fig. 4) to terminal block (see 'b' Fig. 4).
Make electrical connections as shown in Fig. 6 and fi x cable in back panel using
cable gland.

Thermal Safety Cut-Out

The power supply to the heating elements will be interrupted if one or a
combination of the following abnormal events occurs:
1.
Air inlet grilles are obstructed.
2.
Internal ventilation is impaired due to build up of dust and fl uff .
3.
Blower unit stalls.
NOTE:
Before re-setting the reason for activation must be
determined and corrective action taken.
The CFS30E has an electrical reset cut-out which requires the power supply to be
removed for a short period of time to allow the cut-out to cool down. On return of
the power supply, the heater should operate normally.