Download Print this page

Procedure For Resetting Cut-Out; Cleaning - Dimplex AC3CN User Manual

Recessed ceiling heater/ over door heater

Advertisement

Thermal Safety cut-out(s)
The power supply to the heating elements will be interrupted if one or a
combination of the following abnormal events occur:
1.
Air inlet/outlet panel is obstructed.
2.
I n t e r n a l v e n t i l a t i o n i s i m p a i r e d d u e t o b u i l d u p o f d u s t
and fl uff.
3.
Blower unit stalls.
Note : If the cut-out operates, the heater must be turned off immediately to
avoid damage to the heater. Please follow the 'Procedure for resetting cut-
out(s)' explained below.
Procedure for resetting cut-out(s)
Establish the cause and eliminate the fault.
Reset the thermal cut-out(s), located behind the air outlet (for detail view see
Fig. 11).
Press the black reset button (see 'g' in Fig. 11) on the side of the cut-out (see
'f' in Fig. 11) as described in steps 2 - 4 :-
Steps to reset cut-out(s)
1.
Disconnect the power supply.
2.
Pass small fl at head screwdriver through air inlet/outlet panel 'B' to button
side of the cut-out (see 'g' in Fig. 11) avoiding contact with the element
(see 'e' in Fig. 11).
3.
Press the reset button in direction shown in Fig. 11 to reset the cut-out.
(cut-out clicks when reset)
4.
Remove the screwdriver carefully.
5.
Turn on the supply.
If the cut-out continues to operate, the heater should be switched off and an
engineer called.
e
f
g
Maintenance
WARNING: ALWAYS DISCONNECT HEATER FROM THE POWER SUPPLY
BEFORE ATTEMPTING ANY MAINTENANCE.
The heater should be serviced annually. Any dust or debris should be
removed from the grille and elements, taking care not to damage the
elements.
Cleaning the Heater & Switch Panel
External and grille appearance can be maintained by occasionally vacuuming
and wiping with a light duster. External appearance of the switch panel can be
maintained by wiping occasionally with a duster or for stain removal, a weak
soap solution can be applied with a cloth and the surface wiped dry.
Note: Care must be taken to avoid any moisture ingress into the switch
panel.
After Sales Service
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free of
charge provided it has been installed and operated in accordance with these
instructions.
Your rights under this guarantee are additional to your statutory rights, which
in turn are not affected by this guarantee.
Should you require after sales information or assistance with this product
please go to www.dimplex.co.uk where you will fi nd our self help guide by
clicking on "After Sales" or ring our helpdesk on the number shown on the rear
of this booklet.
Please retain your receipt as proof of purchase.