Testing The System - Geoquip GeoZone A Installation Manual

Table of Contents

Advertisement

LED is operated. If climb is not detected, move the Climb Jumper to the
'Medium' position and re-adjust the 'Climb' potentiometer until the red alarm led
is operated. If climb is still not detected, move the Climb Jumper to the 'High'
position and re-adjust the 'Climb' potentiometer until the red alarm led is
operated.
4.
If the climb detection is not good enough with the 'FENCE' setting set to
'SOFT', set the 'FENCE' link to 'HARD' and repeat the procedure above.
5.
Replace the Cut jumper to the position it was removed from.
6.
Replace the lid and check the lid tamper switch lever is in the down position. A
'click' should be heard as the lid is being closed.
The system is now fully operational and set to detect both cut and climb over modes of
attack.

14.6 Testing The System

Additional testing should be carried out to verify that the response at different points
along the fence line is adequate, particularly at points where intrusions are likely to
occur.