Technical Specifications; Installation And Start-Up; Filling The Reservoir - Bell HP250 Use And Maintenance Manual

Air pump rc + remote control
Table of Contents

Advertisement

Available languages

Available languages

4 - TECHNICAL SPECIFICATIONS

Model
Air inlet pressure (bar•)
Maximum working pressure (bar•)
Maximum rated flow (l/min)•
Air connection (standard*)
Oil connection (standard*)
Max. weight (kg)
Reservoir capacity / usable capacity (l)
Dimensions (mm)
Noise level
Recommended oil types

5 - INSTALLATION AND START-UP

This chapter describes the methods of installation of the pump. The method here recommended will give excellent results. The purchaser
of the pump, i.e. the manufacturer of the machine on which the pump will be installed, may opt for different types of installation, using
brackets or any other types of accessories considered to be necessary. HOWEVER, THE ORIGINAL SHAPE AND ATTACHMENT OF
THE PUMP MUST NOT BE MODIFIED, THE PROTECTIONS APPLIED TO THE PUMP MUST NOT BE TAMPERED WITH AND NO
ACTION MUST BE TAKEN THAT COULD MAKE THE PUMP POTENTIALLY DANGEROUS. If these instructions are disregarded, the
person who is responsible for the modifications automatically assumes full liability for any accidents that may occur during use of the pump.
THE PUMP MUST BE INSTALLED ONLY IN HORIZONTAL POSITION.
Figure 2 on page 2 shows the drilling template to use when designing the pump baseplate.
WARNING:
IF THE PUMP'S CONTROLS ARE ExPOSED TO FALLING OBjECTS OR SOMETHING OTHER THAT COULD
ACCIDENTALLY HIT THEM AND CAUSE AN UNExPECTED START-UP, IT IS NECESSARY TO INSTALL AN
APPROPRIATE PROTECTION IN ORDER TO AVOID THIS HAZARD AND RESTORE THE SYSTEM SECURITY.
THE PROTECTION MUST STAND ON TO THE CONTROL MECHANISM.
5.1 - Filling the reservoir (if the pump is supplied without oil)
The table "TECHNICAL SPECIFICATIONS" shows the oil quantities required to fill the pump reservoir. The same table shows the actual
usable oil capacities also.
Use the oil types specified in the table. The use of oil with different characteristics can result in serious damage to the pump and render
it unsuitable for use.
THE MANUFACTURER SHALL NOT BE HELD RESPONSIBLE FOR INjURY TO PEOPLE OR DAMAGE TO
PROPERTY CAUSED BY THE USE OF UNSUITABLE OR ExHAUST OIL.
DAMAGE TO THE PUMP RESULTING FROM THE ABOVE MENTIONED CAUSES IS NOT COVERED BY
WARRANTY.
● Use a hexagon spanner ø 17 to remove the filler plug (fig.6, page 3).
● Pour the correct quantity of oil into the reservoir (refer to the table "TECHNICAL SPECIFICATIONS")
● Clean the opening using a clean cloth and refit the plug, screwing it in completely.
14
HP 250
HP 500
RC
RC
250
500
2,0
1,3
1/4" GAS
3/8" - 18 NPTF
~ 1,4 / 1,1
Pump dimensions are shown on page 2, figure 1
80 dB(A) / 1m
MOBIL DTE 11 - SHELL TELLUS OIL T 15
CASTROL HYSPIN AWH15 - or equivalent
HP 700
HP 1000
RC
RC
5 ÷ 8
700
1000
0,7
0,6
~ 5,3
193551070 v.1 - UPD 06022020