Installation

Make sure that the scanner has the correct cable to plug in the PC as
below described:
*Note : Please install PL-2303 driver for USB serial

Auto-sensing setup

The auto-sensing features works
when putting scanner on stand.
When scanner removes from stand,
scanner will become trigger mode.

Reset Configuration to Defaults

(For RS232, USB serial)
If you are unsure of the scanner configuration or have scanned the
incorrect codes, please scan the "Set Factory default" barcode. This
will reset the scanner to its factory defaults.
Default

READING MODE

Scan
(Level)
* Scan (Level) - A trigger pull activates the laser and decode
processing. The laser remains on and decode processing continues
until a trigger release, a valid decode, or the Laser On Time-out is
reached.
* Scan (Pulse) - A trigger pull activates the laser and decode
processing. The laser remains on and decode processing continues
until a valid decode or the Laser On Time-out is reached.

Redundancy Level

This scanner offers two levels of decode redundancy. Select higher
redundancy levels for decreasing levels of bar code quality. As
redundancy levels increase, the decoder's aggressiveness decreases.
Select the redundancy level appropriate for the bar code quality.
Redundancy Level 1
barcode must be successfully read twice
before being decoded
Redundancy Level 2
barcode must be successfully read three times
before being decoded:

1D Symbologies On/OFF -1

ENABLE
ENABLE
ENABLE
Scan
(Pulse)
ENABLE
ENABLE
ENABLE
ENABLE
ENABLE
ENABLE
ENABLE
Code 128
DISABLE
ISBT 128
DISABLE
Code 39
DISABLE
Code 39
FULL ASCII
DISABLE
Trioptic
Code 39
DISABLE
UPC-A
DISABLE
UPC-E
DISABLE
EAN-8
DISABLE
EAN-13
DISABLE
CODABAR
DISABLE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS6302A and is the answer not in the manual?

Questions and answers

Summary of Contents for RIOTEC LS6302A

  • Page 1 1D Symbologies On/OFF -1 Reset Configuration to Defaults Programming Quick Guide (For RS232, USB serial) If you are unsure of the scanner configuration or have scanned the LS6302A./ FS5022A ENABLE Code 128 DISABLE incorrect codes, please scan the “Set Factory default” barcode. This will reset the scanner to its factory defaults.
  • Page 2 ENABLE DISABLE GS1 DataBar Limited Interleaved 25 ENABLE DISABLE ENABLE DISABLE GS1 DataBar Expanded ENABLE Discrete 25 DISABLE ENABLE DISABLE  Information in this document is subject to change without notice.  For more information, please visit:  www.riotec.com.tw R_140708_01 2 ...

This manual is also suitable for:

Fs5022a

Table of Contents