Panduit PAT1M Operation Manual page 36

Automatic cable tie installation system
Hide thumbs Also See for PAT1M:
Table of Contents

Advertisement

Error Message
6. Dispenser Jam - Check Tie
Loading
7. Jaw Sensor Error
8. Detent Sensor Blocked or Dirty
9. Blocked Hose - Failed Back
Pressure Test
INCORRECT CABLE TIE
(Long cut-off / tail)
• Cable ties are too moist
(due to high humidity)
- Turn down tension until correct
cut-off occurs.
PAT1M/PAT1.5M: PA22222A01_03
Downloaded from
Elcodis.com
electronic components distributor
PAT1M / PAT1.5M OPERATION MANUAL
CABLE TIE CONDITION FACTORS
CUT-OFF
Corrective Action
a. Press "Buzzer" button, open Dispenser door, Press
"Unload" button while pulling back lightly on strip of
cable ties until all cable ties are removed. Cut off bad
cable ties and reload.
b. If having trouble clearing jam, contact Maintenance
Department. (Note: Don't pry on white plastic roller; will
cause damage.
Contact Maintenance Department
CORRECT CABLE TIE
CUT-OFF
Page: 34 of 36
CABLE TIE DETACHES
FROM BUNDLE
• Cable ties are too brittle
(due to dry conditions)
- Take new reel of ties out of
original bag.
- Place new ties on PDM.
- Place used reel in bag with
damp paper towel or
sponge to recondition.
Dec., 2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pat1.5m

Table of Contents