E. Reversing drive motor operates in one (1) direction only, stops, and restarts in same direction
(for reversing models only)...
1. Failed reversing contactor (relay).
2. Failed reversing timer.
F.
Heating unit is not operating (ALL temperature selections)...
GAS MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment or has failed.
b. Sail switch is not closing or fluttering...
1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Failed burner hi-limit circuit.
3. Failed lint compartment automatic (225º F [107º C]) safety thermostat circuit.
4. Failed heat selector switch.
ELECTRIC MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment or has failed.
b. Sail switch is not closing or fluttering...
1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Failed oven hi-limit circuit.
3. Failed lint compartment automatic (225º F [107º C]) safety thermostat circuit.
4. Failed oven contactor/relay.
5. Failed heat selector switch.
STEAM MODELS ONLY
1. Steam damper binding and/or stuck.
2. Failed lint compartment automatic (225º F [107º C]) safety thermostat circuit.
3. Failed heat selector switch.
113066 - 17