N. Dryer stops during a cycle and light emitting diode (L.E.D.) display returns to "FILL"...
1. Fault in microprocessor heat sensor circuit...
a. Loose connection in wires between temperature sensor and microprocessor controller (computer).
2. Loose connection somewhere in main power circuit to microprocessor controller (computer).
O. No heat (for gas models only)...ignitor sparks, burner goes on and off right away...
1. Direct Spark Ignition (DSI) ignitor/flame-probe is out of adjustment...reposition closer to the flame area.
2. Sail switch is fluttering...
a. Lint screen is dirty.
b. Restriction in exhaust ductwork.
3. Insufficient make-up air.
4. Failed ignitor/flame-probe assembly.
5. Failed DSI module.
6. Failed gas valve.
P.
Heating unit is not operating (no heat) and heat indicator dot is on...
GAS MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment or has failed.
b. Sail switch damper is not closing or is fluttering...
1) Lint screen is dirty.
2) Restriction in exhaust ductwork.
2. Fault in burner hi-limit circuit or thermostat.
3. Fault in lint chamber sensor bracket hi-heat protector thermostat.
4. Failed DSI module.
5. Failed DSI ignitor/flame-probe assembly.
6. Failed microprocessor controller (computer).
113066 - 17