R.V.R. Electronica PJ700C-LCD User Manual page 16

Table of Contents

Advertisement

PJ500C-LCD, PJ700C-LCD & PJ1000light
The bottom line provides instantaneous power reading (997W in this instance);
press button
the desired level, press ENTER to confirm and exit the default menu. Please note
that the setting is stored automatically; in other words, if you press ESC or do not
press any keys before the preset time times out, the latest power level set will be
retained.
NOTE: This feature prevents the machine from delivering maximum power as
soon as output is enabled from menu 4, or in the event the machine is already
set to ON and energised.
2) Ensure that machine is not in a locked-out state. Press the ESC key (chap.
6.1) to call up the selection screen (Menu 3). Highlight Fnc and press ENTER
to confirm (chap. 6.1) and access the appropriate menu (menu 4).
If LOC is set to REMOTE (machine remote control), move cursor to LOC and
press ENTER (chap. 6.1); label will change to LOCAL, i.e. local control operation
mode.
In the same menu, ensure that power limiting is disabled: if PWR is set to OFF,
i.e. power output is disabled, move cursor to PWR. Press ENTER (chap. 6.1)
and label will switch to ON, i.e. power output enabled.
Press ESC (chap. 6.1) twice to go back to the default menu (menu 1).
3) Fine tune power setting from menu 2 (see description of item 1b) until achieving
the desired value.
WARNING:Equipment is capable of delivering more than rated output power
(500W for PJ500C-LCD, 700W for PJ700C-LCD or 1000 W for PJ1000-LIGHT);
however, never exceed the specified power rating.
NOTE: Exciter drive power setting should never exceed 20W, or it will trigger an
Overdrive Alarm.
NOTE: If power is set to 0 W in the edit mode, the INTERLOCK OUT contact
(chap. 6.2) trips and external exciter power is immediately inhibited.
Next, you can review all operating parameters of the machine through the
management firmware.
Normally, the machine can run unattended. Any alarm condition is handled
automatically by the safety system or is signalled by the LED indicators on the
panel or by display messages.
NOTE: Standard factory settings are: output power set to upper limit (unless
otherwise specified by customer) and OFF.