  • Page 2: Safety Instruction

    Thank you for purchasing a lead free soldering station. It is designed for lead free soldering. Please read this manual before operating the unit. Store this manual in a safe, easily accessible place for future reference. Safety Instruction WARNING In this instruction manual,“Warning” “Caution”and“Note”are defined as follows: WARNING: Misuse may potentially cause death of, or serious injury to the user.
  • Page 3 ● Advise other people in the working area to turn the power off when in a break or after using the equipment because the unit can reach a very high temperature and may cause potentially dangerous. ● No replace any parts or install the tips before turning the power off and cooling down the searing-iron to room temperature.
  • Page 4: Specification And Characteristic

    2.Specification and characteristic Page2 Page3 2.1 Specification Power Output voltage The temperature range of the iron 80℃~480℃ The temperature range of the sleeping 50℃~250℃ The time range of the sleeping 0~250 (unit: minute) The time range of the shutting 0~250 (unit: minute) ±2℃...
  • Page 5 Outer Dimension 2 Add a little water to the iron holder. The small sponge will absorb the water to keep the large 15.5*7.8*12(unit: mm) Weight (Without power cord) sponge above it wet all times. It may only use big sponge and not use small one. 3 Dampen the larger cleaning sponge and place it on the iron holder base.
  • Page 6 the heating element” and install it after confirming it is well. 6 Tie up the heating element and the handle cord with the strap. 7 Put the heating element into handle according to the opposite order of disassembling, and the heating element must be put into bottom.
  • Page 7 about four seconds, the station will come into the normal work process, and it can set the CAUTION: temperature. 3. Input the new password: Be sure to turn off the power switch before connecting or disconnecting the soldering iron. Failure to do so may damage the soldering station. Note: the next inputted password must be same with the last inputted password, and then the 1.Connect the connector plug of the iron handle cord to the socket in front of the soldering station.
  • Page 8 4.6 check and a. Between pins 4&5 ( ) Under 1Ω(Normal) Heating Element b. Between pins 1&2 ( Under 10Ω(Normal) Sensor replace c. Between pins 1& Tip Under 2Ω soldering iron Note: * when checking b and c items in the table, the soldering iron must be equipped with tip.
  • Page 9 3.3.4 Other setting cooling down to the room temperature. 1 press the “△”or “▽”key can change the setting value. 1 If the values of „a‟ and „b‟ are different from the values in the following table, replace the heating element or sensor or cord assembly. Refer to the following steps. Press * key Press* key Select working mode...
  • Page 10 The soldering iron must be placed at the soldering iron station. And only in this state, the soldering station can sleep automatically when up to the setting time. 4.5 Error messages * The solder station will not into sleep when the sleeping time is 000. And the solder will sleep at once when the setting sleeping time is 001 and the handle is placed at Various error messages will be displayed when there is something wrong with the device.
  • Page 11: Calibrating The Temperature

    in sleeping state, the iron‟s temperature will fall down to 200℃. 4.3 check and clean the tip If the setting sleeping temperature is 200℃ and the setting work temperature is 150℃, 1 Set the temperature to 250℃. in sleeping state, the iron‟s temperature in sleeping will fall down to 150℃. 2 When the temperature stabilizes, clean the tip with the cleaning sponge and check the condition 5 up temp setting of the tip.
  • Page 12 3 Methods of recalibrating the temperature: 1) Set the temperature of the soldering station to a certain value. 2) When the temperature stabilizes, measure the tip‟s temperature with thermometer and write down the values. 3) Press “*” key unlooseningly and then press the “△”and“▽”keys simultaneously, the soldering station enters the temperature calibration mode and LCD displays “Cal Temp”.