Buttonmessage - LINOVISION IOT-CPANEL Quick Start Manual

Lorawan smart scene panel
Table of Contents

Advertisement

09 (Hardware Version)
0a (Software Version)
0b (Power On)
16 (Device SN)
Example:
ff0bff ff0101 ff166592b32851010013ff090100 ff0a0102
Channel
Type
0b
ff
(Power On)
Channel
Type
16(Device
ff
SN)
Channel
Type
0a
ff
(Software
version)
5.2Button Message
IOT-CPANEL reports battery level according to reportinginterval (1080 mins by default) and
button message when buttonis pressed.
Channel
01
ff
34(Button Message)
Example:
Channel
01
Channel
ff
Note: if you press one button more than 6 times in a row, the 7
delay delivery.
01 40 =>V1.4
01 14 =>V1.14
Device is on
16 digits
Value
ff (Reserved)
Value
6592b328510
10013
Value
0102
(V1.2)
Type
75(Battery Level)
UINT8, Unit: %
Byte 1: Button Number
Byte 2-3:Button LoRa D2DCommand,
the command is 01-06by default.
01 75 64
Type
75 (Battery)
ff 34 01 18 00
Type
34(Button
Message)
Channel
Type
01
ff
(Protocol Version)
Channel
Type
09
ff
(Hardware version)
Description
Value
64 =>100%
Value
01 =>Button 1
18 00=>Thisbutton LoRa D2D
command is 0018
th
and follow-upmessages will
Value
01 (V1)
Value
0100
(V1.0)