7. Precautions and WEEE Directive
Cautions to Be Taken for This Product:
Do not let the connectors or test pins of the R0E001000ACB00, or the flexible cable come in contact with conductive
materials.
Do not touch the connectors or test pins of the R0E001000ACB00 directly. Static electricity may damage the internal
circuits.
Be careful not to apply a mechanical shock to the CN3 connector of the R0E001000ACB00. Impact may bend the pins.
Make sure there is no bend in the CN3 connector pins of the R0E001000ACB00 before use. Short circuits may damage
the internal circuits.
Do not flex the flexible cable excessively. The cable may cause a break.
Do not tape the flexible cable or apply adhesives to secure the cable. The shielding material on the surface of the cable
may come off.
Note on Electrical Characteristics:
By using the flexible cable for extension, the DC resistance will increase (approximately 5Ω per one line), so that the
electrical transmission characteristics, etc, become worse. When problems occur, such as a difference in timing
between the user system and the MCU unit, do not use this product.
Notes on This Product:
We cannot accept any request for repair.
Disposal Instruction (This is only valid in the European Union.):
Renesas development tools and products are directly covered by the European Union's Waste Electrical and Electronic
Equipment, (WEEE), Directive 2002/96/EC. As a result, this equipment, including all accessories, must not be disposed
of as household waste but through your locally recognised recycling or disposal schemes. As part of our commitment to
environmental responsibility Renesas also offers to take back the equipment and has implemented a Tools Product
Recycling Program for customers in Europe. This allows you to return equipment to Renesas for disposal through our
approved Producer Compliance Scheme. To register for the program, click here "http://www.renesas.com/weee"
8. Correspondence of Connectors CN1, CN2 and CN3
The pin connections between CN1 and CN2 are one-to-one. Refer to the correspondence table of the user's manual of the converter
board to find the pins to connect to CN3. For example, if CN1-5 of the converter board corresponds to Pin No. IC1-10, Pin No.
CN3-2 of the R0E001000ACB00 corresponds to Pin No. IC1-10.
Table 2 Correspondence of the connectors
CN3 Pin No.
CN1,2 Pin No.
1
2
2
5
3
6
4
7
5
8
6
9
7
10
8
11
9
12
10
13
11
14
12
15
13
16
14
17
15
18
16
19
17
20
18
21
19
22
20
23
21
24
22
25
REJ10J2091-0200 Rev.2.00
Apr 16, 2010
IMPORTANT
CN3 Pin No.
CN1,2 Pin No.
23
26
24
27
25
28
26
29
27
30
28
31
29
32
30
33
31
34
32
35
33
36
34
37
35
38
36
39
37
40
38
41
39
42
40
43
41
44
42
45
43
46
44
47
CN3 Pin No.
CN1,2 Pin No.
45
54
46
55
47
56
48
57
49
58
50
59
51
60
52
61
53
62
54
63
55
64
56
65
57
66
58
67
59
68
60
69
61
70
62
71
63
72
64
73
65
74
66
75
User's Manual
.
CN3 Pin No.
CN1,2 Pin No.
67
76
68
77
69
78
70
79
71
80
72
81
73
82
74
83
75
84
76
85
77
86
78
87
79
88
80
89
81
90
82
91
83
92
84
93
85
94
86
95
87
96
88
99
Page 3 of 4

Advertisement

loading